{"title":"20kv绝缘子漏电流试验室温湿度控制装置设计","authors":"Lastoni Wibowo, A. Syakur, T. Andromeda","doi":"10.1109/ICITACEE.2019.8904318","DOIUrl":null,"url":null,"abstract":"Measurement of the Leakage Current in a Test Chamber needs to be done to find out the durability characteristics of 20kV insulator against high-voltage. Durability of insulating material especially 20 kV insulator was heavily influenced by the state of the environment, particularly the temperature and humidity are very diverse, therefore to obtain accurate test results required a test chamber with temperature and humidity similar to State of the environment. However, the currently test chamber that often used for testing of insulating material does not have temperature and humidity controller so that the test results of electrical materials are not accurate. In this paper, a 20 kV isolator leakage current test chamber is designed with a temperature and humidity regulator applies an on-off control method implanted in Arduino Uno Rev.3 that can condition the test chamber to resemble environmental conditions to obtain accurate test results. In this paper the temperature setting is carried out at three set points namely a maximum temperature of 33 ° C with a minimum humidity of 58%, an average temperature of 27 ° C with an average humidity of 82% and a minimum temperature of 21 ° C with a maximum humidity of 91%. The measurement results show that the maximum temperature setting with minimum humidity obtained the highest temperature measurement results of 33.30 ° C and the lowest humidity of 58.25%. In the average temperature setting with average humidity, the measurement results obtained near the set point, namely the temperature of 27.25 ° C with a humidity of 81.60%. While the minimum temperature setting with maximum humidity obtained the measurement results closest to the set point that is the temperature of 25.35 ° C with a humidity of 91.50%","PeriodicalId":319683,"journal":{"name":"2019 6th International Conference on Information Technology, Computer and Electrical Engineering (ICITACEE)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Design Of Temperature And Humidity Control Devices In The Leakage Current Test Chamber Of 20 kV Insulator\",\"authors\":\"Lastoni Wibowo, A. Syakur, T. Andromeda\",\"doi\":\"10.1109/ICITACEE.2019.8904318\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measurement of the Leakage Current in a Test Chamber needs to be done to find out the durability characteristics of 20kV insulator against high-voltage. Durability of insulating material especially 20 kV insulator was heavily influenced by the state of the environment, particularly the temperature and humidity are very diverse, therefore to obtain accurate test results required a test chamber with temperature and humidity similar to State of the environment. However, the currently test chamber that often used for testing of insulating material does not have temperature and humidity controller so that the test results of electrical materials are not accurate. In this paper, a 20 kV isolator leakage current test chamber is designed with a temperature and humidity regulator applies an on-off control method implanted in Arduino Uno Rev.3 that can condition the test chamber to resemble environmental conditions to obtain accurate test results. In this paper the temperature setting is carried out at three set points namely a maximum temperature of 33 ° C with a minimum humidity of 58%, an average temperature of 27 ° C with an average humidity of 82% and a minimum temperature of 21 ° C with a maximum humidity of 91%. The measurement results show that the maximum temperature setting with minimum humidity obtained the highest temperature measurement results of 33.30 ° C and the lowest humidity of 58.25%. In the average temperature setting with average humidity, the measurement results obtained near the set point, namely the temperature of 27.25 ° C with a humidity of 81.60%. While the minimum temperature setting with maximum humidity obtained the measurement results closest to the set point that is the temperature of 25.35 ° C with a humidity of 91.50%\",\"PeriodicalId\":319683,\"journal\":{\"name\":\"2019 6th International Conference on Information Technology, Computer and Electrical Engineering (ICITACEE)\",\"volume\":\"53 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 6th International Conference on Information Technology, Computer and Electrical Engineering (ICITACEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICITACEE.2019.8904318\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 6th International Conference on Information Technology, Computer and Electrical Engineering (ICITACEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICITACEE.2019.8904318","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
为了了解20kV绝缘子在高压下的耐久特性,需要在试验箱中测量泄漏电流。绝缘材料特别是20kv绝缘子的耐久性受环境状态的影响很大,特别是温度和湿度变化很大,因此要获得准确的试验结果,就需要一个温度和湿度与环境状态相似的试验箱。然而,目前常用于绝缘材料测试的试验箱没有温湿度控制器,导致电气材料的测试结果不准确。本文设计了一个20 kV隔离器漏电流试验箱,温湿度调节器采用植入Arduino Uno Rev.3的开关控制方法,使试验箱适应环境条件,获得准确的试验结果。本文的温度设置有三个设定点:最高温度33℃,最小湿度58%;平均温度27℃,平均湿度82%;最低温度21℃,最大湿度91%。测量结果表明,在最小湿度的最高温度设置下,获得的最高温度测量结果为33.30℃,最低湿度为58.25%。在平均温度、平均湿度设置中,测量结果接近设定点,即温度为27.25℃,湿度为81.60%。而在最大湿度下的最低温度设置得到的测量结果最接近设定点,即温度为25.35℃,湿度为91.50%
Design Of Temperature And Humidity Control Devices In The Leakage Current Test Chamber Of 20 kV Insulator
Measurement of the Leakage Current in a Test Chamber needs to be done to find out the durability characteristics of 20kV insulator against high-voltage. Durability of insulating material especially 20 kV insulator was heavily influenced by the state of the environment, particularly the temperature and humidity are very diverse, therefore to obtain accurate test results required a test chamber with temperature and humidity similar to State of the environment. However, the currently test chamber that often used for testing of insulating material does not have temperature and humidity controller so that the test results of electrical materials are not accurate. In this paper, a 20 kV isolator leakage current test chamber is designed with a temperature and humidity regulator applies an on-off control method implanted in Arduino Uno Rev.3 that can condition the test chamber to resemble environmental conditions to obtain accurate test results. In this paper the temperature setting is carried out at three set points namely a maximum temperature of 33 ° C with a minimum humidity of 58%, an average temperature of 27 ° C with an average humidity of 82% and a minimum temperature of 21 ° C with a maximum humidity of 91%. The measurement results show that the maximum temperature setting with minimum humidity obtained the highest temperature measurement results of 33.30 ° C and the lowest humidity of 58.25%. In the average temperature setting with average humidity, the measurement results obtained near the set point, namely the temperature of 27.25 ° C with a humidity of 81.60%. While the minimum temperature setting with maximum humidity obtained the measurement results closest to the set point that is the temperature of 25.35 ° C with a humidity of 91.50%