{"title":"光学设置的不灵敏度和个人方程误差","authors":"J. Guild","doi":"10.1088/1475-4878/31/1/302","DOIUrl":null,"url":null,"abstract":"The paper contains the results of observations on the insensitivity, that is, mean difference of the individual observations of a large series from the mean of the series, in the case of X type graticules set on vertical object lines. The influence of the following factors was investigated: Thickness of cross-wires. Angle between cross-wires. Field brightness. Pupillary aperture. Observations were also made of the magnitude of the personal equation error in such settings.","PeriodicalId":405858,"journal":{"name":"Transactions of The Optical Society","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1929-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"The insensitivity and personal equation errors of optical settings\",\"authors\":\"J. Guild\",\"doi\":\"10.1088/1475-4878/31/1/302\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper contains the results of observations on the insensitivity, that is, mean difference of the individual observations of a large series from the mean of the series, in the case of X type graticules set on vertical object lines. The influence of the following factors was investigated: Thickness of cross-wires. Angle between cross-wires. Field brightness. Pupillary aperture. Observations were also made of the magnitude of the personal equation error in such settings.\",\"PeriodicalId\":405858,\"journal\":{\"name\":\"Transactions of The Optical Society\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1929-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transactions of The Optical Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/1475-4878/31/1/302\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of The Optical Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1475-4878/31/1/302","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The insensitivity and personal equation errors of optical settings
The paper contains the results of observations on the insensitivity, that is, mean difference of the individual observations of a large series from the mean of the series, in the case of X type graticules set on vertical object lines. The influence of the following factors was investigated: Thickness of cross-wires. Angle between cross-wires. Field brightness. Pupillary aperture. Observations were also made of the magnitude of the personal equation error in such settings.