E. Sazonov, K. Metcalfe, P. López-Meyer, Stephen T. Tiffany
{"title":"用于监测吸烟的射频手势传感器","authors":"E. Sazonov, K. Metcalfe, P. López-Meyer, Stephen T. Tiffany","doi":"10.1109/ICSENST.2011.6137014","DOIUrl":null,"url":null,"abstract":"Today, over a billion people in the world are smokers. Smoking is associated with increased risk of cardiovascular disease, chronic obstructive pulmonary disease, emphysema, and various cancers, causing approximately 6 million premature deaths per year. Current methods of assessing smoking behavior (e.g., self-report, portable puff-topography instruments) do not permit the collection of accurate, non-reactive measures that capture real-time smoking frequency and comprehensive within-cigarette puff topography. Our goal is development of a noninvasive wearable sensor system (Personal Automatic Cigarette Tracker - PACT) that is completely transparent to the end user and does not require any conscience effort to achieve reliable monitoring of smoking behavior in free living individuals. A key component of PACT is a sensor that captures a characteristic hand-to-mouth gesture preceding cigarette smoke inhalations. This paper details design and validation of a wearable radio-frequency proximity sensor that measures the distance between an individual's wrist and chest in real-time. Hand-to-mouth gestures detected with this device provide quantitative data that can be used for analysis of behavioral patterns during smoking and other activities.","PeriodicalId":202062,"journal":{"name":"2011 Fifth International Conference on Sensing Technology","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"36","resultStr":"{\"title\":\"RF hand gesture sensor for monitoring of cigarette smoking\",\"authors\":\"E. Sazonov, K. Metcalfe, P. López-Meyer, Stephen T. Tiffany\",\"doi\":\"10.1109/ICSENST.2011.6137014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Today, over a billion people in the world are smokers. Smoking is associated with increased risk of cardiovascular disease, chronic obstructive pulmonary disease, emphysema, and various cancers, causing approximately 6 million premature deaths per year. Current methods of assessing smoking behavior (e.g., self-report, portable puff-topography instruments) do not permit the collection of accurate, non-reactive measures that capture real-time smoking frequency and comprehensive within-cigarette puff topography. Our goal is development of a noninvasive wearable sensor system (Personal Automatic Cigarette Tracker - PACT) that is completely transparent to the end user and does not require any conscience effort to achieve reliable monitoring of smoking behavior in free living individuals. A key component of PACT is a sensor that captures a characteristic hand-to-mouth gesture preceding cigarette smoke inhalations. This paper details design and validation of a wearable radio-frequency proximity sensor that measures the distance between an individual's wrist and chest in real-time. Hand-to-mouth gestures detected with this device provide quantitative data that can be used for analysis of behavioral patterns during smoking and other activities.\",\"PeriodicalId\":202062,\"journal\":{\"name\":\"2011 Fifth International Conference on Sensing Technology\",\"volume\":\"48 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"36\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Fifth International Conference on Sensing Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENST.2011.6137014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Fifth International Conference on Sensing Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2011.6137014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
RF hand gesture sensor for monitoring of cigarette smoking
Today, over a billion people in the world are smokers. Smoking is associated with increased risk of cardiovascular disease, chronic obstructive pulmonary disease, emphysema, and various cancers, causing approximately 6 million premature deaths per year. Current methods of assessing smoking behavior (e.g., self-report, portable puff-topography instruments) do not permit the collection of accurate, non-reactive measures that capture real-time smoking frequency and comprehensive within-cigarette puff topography. Our goal is development of a noninvasive wearable sensor system (Personal Automatic Cigarette Tracker - PACT) that is completely transparent to the end user and does not require any conscience effort to achieve reliable monitoring of smoking behavior in free living individuals. A key component of PACT is a sensor that captures a characteristic hand-to-mouth gesture preceding cigarette smoke inhalations. This paper details design and validation of a wearable radio-frequency proximity sensor that measures the distance between an individual's wrist and chest in real-time. Hand-to-mouth gestures detected with this device provide quantitative data that can be used for analysis of behavioral patterns during smoking and other activities.