{"title":"基于广义预测控制的闭环人工胰腺风险分析","authors":"Wenping Liu, Haoyu Jin","doi":"10.1109/ICCIA49625.2020.00037","DOIUrl":null,"url":null,"abstract":"An improved generalized predictive control (GPC) algorithm with two adaptive strategies, namely, an adaptive reference glucose trajectory (AT) and an adaptive softening factor (AF), was proposed for artificial pancreas systems (AP) in our previous research. Tests with the UVA/Padova type 1 diabetes mellitus simulator (T1DMS), approved by the US Food and Drug Administration, showed that it realized an effective control of the blood glucose concentrations (BGCs) of adult and adolescent patients with type 1 diabetes. Here, risk analysis was further performed for the GPC controllers with 20 in-silico subjects (10 adults and 10 adolescents). Two indexes provided by the UVA/Padova T1DMS, including low blood glucose index (LBGI) and high blood glucose index (HBGI), were used to analyze the long-term risks for hypoglycemia and hyperglycemia of the GPC controllers. Results showed that both adult and adolescent groups had minimal risks for hypoglycemia and hyperglycemia with our GPC controllers. Moreover, AT strategy played a better role in preventing hypoglycemia and AF strategy played a better role in preventing hyperglycemia. Thus, the GPC+AT+AF controller is effective and safe, and it could be potentially applied in the AP systems.","PeriodicalId":237536,"journal":{"name":"2020 5th International Conference on Computational Intelligence and Applications (ICCIA)","volume":"72 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Risk analysis of a closed-loop artificial pancreas based on generalized predictive control\",\"authors\":\"Wenping Liu, Haoyu Jin\",\"doi\":\"10.1109/ICCIA49625.2020.00037\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An improved generalized predictive control (GPC) algorithm with two adaptive strategies, namely, an adaptive reference glucose trajectory (AT) and an adaptive softening factor (AF), was proposed for artificial pancreas systems (AP) in our previous research. Tests with the UVA/Padova type 1 diabetes mellitus simulator (T1DMS), approved by the US Food and Drug Administration, showed that it realized an effective control of the blood glucose concentrations (BGCs) of adult and adolescent patients with type 1 diabetes. Here, risk analysis was further performed for the GPC controllers with 20 in-silico subjects (10 adults and 10 adolescents). Two indexes provided by the UVA/Padova T1DMS, including low blood glucose index (LBGI) and high blood glucose index (HBGI), were used to analyze the long-term risks for hypoglycemia and hyperglycemia of the GPC controllers. Results showed that both adult and adolescent groups had minimal risks for hypoglycemia and hyperglycemia with our GPC controllers. Moreover, AT strategy played a better role in preventing hypoglycemia and AF strategy played a better role in preventing hyperglycemia. Thus, the GPC+AT+AF controller is effective and safe, and it could be potentially applied in the AP systems.\",\"PeriodicalId\":237536,\"journal\":{\"name\":\"2020 5th International Conference on Computational Intelligence and Applications (ICCIA)\",\"volume\":\"72 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 5th International Conference on Computational Intelligence and Applications (ICCIA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCIA49625.2020.00037\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 5th International Conference on Computational Intelligence and Applications (ICCIA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCIA49625.2020.00037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

针对人工胰腺系统(AP),提出了一种基于自适应参考血糖轨迹(AT)和自适应软化因子(AF)两种自适应策略的改进广义预测控制(GPC)算法。通过美国食品和药物管理局批准的UVA/Padova 1型糖尿病模拟器(T1DMS)的试验表明,它实现了对成人和青少年1型糖尿病患者血糖浓度(BGCs)的有效控制。本研究对20名计算机受试者(10名成人和10名青少年)的GPC控制者进行了进一步的风险分析。采用UVA/Padova T1DMS提供的低血糖指数(LBGI)和高血糖指数(HBGI)两项指标分析GPC控制者低血糖和高血糖的长期风险。结果显示,使用GPC控制器的成人组和青少年组低血糖和高血糖的风险都很小。此外,AT策略对低血糖的预防效果更好,AF策略对高血糖的预防效果更好。因此,GPC+AT+AF控制器是安全有效的,在AP系统中具有潜在的应用前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Risk analysis of a closed-loop artificial pancreas based on generalized predictive control
An improved generalized predictive control (GPC) algorithm with two adaptive strategies, namely, an adaptive reference glucose trajectory (AT) and an adaptive softening factor (AF), was proposed for artificial pancreas systems (AP) in our previous research. Tests with the UVA/Padova type 1 diabetes mellitus simulator (T1DMS), approved by the US Food and Drug Administration, showed that it realized an effective control of the blood glucose concentrations (BGCs) of adult and adolescent patients with type 1 diabetes. Here, risk analysis was further performed for the GPC controllers with 20 in-silico subjects (10 adults and 10 adolescents). Two indexes provided by the UVA/Padova T1DMS, including low blood glucose index (LBGI) and high blood glucose index (HBGI), were used to analyze the long-term risks for hypoglycemia and hyperglycemia of the GPC controllers. Results showed that both adult and adolescent groups had minimal risks for hypoglycemia and hyperglycemia with our GPC controllers. Moreover, AT strategy played a better role in preventing hypoglycemia and AF strategy played a better role in preventing hyperglycemia. Thus, the GPC+AT+AF controller is effective and safe, and it could be potentially applied in the AP systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信