基于树莓派的减压床垫,配有气压监测系统和漏气检测器

H. Pranjoto, William Chandra Sarwono, Andrew Febrian Miyata, L. Agustine
{"title":"基于树莓派的减压床垫,配有气压监测系统和漏气检测器","authors":"H. Pranjoto, William Chandra Sarwono, Andrew Febrian Miyata, L. Agustine","doi":"10.1109/ic2ie53219.2021.9649373","DOIUrl":null,"url":null,"abstract":"Decubitus ulcers appear when the skin receives intense pressure for a short time or mild pressure for a longer time. Currently, nurses assist immobilized patients to change their position every 2 hours to avoid decubitus ulcers. Another option is using the pressure-reducing mattress. This mattress has the feature to change the pressure strength, but the air pressure and leakage are unknown. Both of these problems will be overcome by the automatic mattress developed in this study. The developed mattress uses gas pressure sensors, a Raspberry Pi, solenoid valves, and an AC air pump. The mattress pumping process is controlled based on the air pressure from 0.7 to 2.1 PSI in 3.5 minutes for each airbag group. The airbags are controlled to form wavelike contours with the feedback from the gas pressure sensors. A prolonged period to reach maximum pressure indicates the air leaks. The testing result shows that the control system can maintain the pressure of the airbag from 0.7 to 2.1 PSI accurately during the pumping process, with or without load on the mat. The accuracy of the pumping duration for each airbag group is 96.31% from the 3.5 minutes goal and gives no meaningful effect to skin pressure.","PeriodicalId":178443,"journal":{"name":"2021 4th International Conference of Computer and Informatics Engineering (IC2IE)","volume":"46 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Raspberry Pi-based Decubitus Reducing Mattress with Air Pressure Monitoring System and Air Leaks Detector\",\"authors\":\"H. Pranjoto, William Chandra Sarwono, Andrew Febrian Miyata, L. Agustine\",\"doi\":\"10.1109/ic2ie53219.2021.9649373\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Decubitus ulcers appear when the skin receives intense pressure for a short time or mild pressure for a longer time. Currently, nurses assist immobilized patients to change their position every 2 hours to avoid decubitus ulcers. Another option is using the pressure-reducing mattress. This mattress has the feature to change the pressure strength, but the air pressure and leakage are unknown. Both of these problems will be overcome by the automatic mattress developed in this study. The developed mattress uses gas pressure sensors, a Raspberry Pi, solenoid valves, and an AC air pump. The mattress pumping process is controlled based on the air pressure from 0.7 to 2.1 PSI in 3.5 minutes for each airbag group. The airbags are controlled to form wavelike contours with the feedback from the gas pressure sensors. A prolonged period to reach maximum pressure indicates the air leaks. The testing result shows that the control system can maintain the pressure of the airbag from 0.7 to 2.1 PSI accurately during the pumping process, with or without load on the mat. The accuracy of the pumping duration for each airbag group is 96.31% from the 3.5 minutes goal and gives no meaningful effect to skin pressure.\",\"PeriodicalId\":178443,\"journal\":{\"name\":\"2021 4th International Conference of Computer and Informatics Engineering (IC2IE)\",\"volume\":\"46 3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 4th International Conference of Computer and Informatics Engineering (IC2IE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ic2ie53219.2021.9649373\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 4th International Conference of Computer and Informatics Engineering (IC2IE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ic2ie53219.2021.9649373","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

当皮肤在短时间内受到强烈的压力或较长时间的轻微压力时,就会出现褥疮。目前,护士协助固定病人每2小时换一次体位,以避免褥疮。另一个选择是使用减压床垫。这个床垫有改变压力强度的功能,但是空气压力和泄漏是未知的。本研究开发的自动床垫将克服这两个问题。开发的床垫使用气体压力传感器、树莓派、电磁阀和交流气泵。气垫泵送过程是在3.5分钟内控制每个安全气囊组的气压从0.7到2.1 PSI。气囊被控制形成波浪状轮廓与气体压力传感器的反馈。长时间达到最大压力表明空气泄漏。测试结果表明,在充气过程中,无论垫上是否有载荷,控制系统都能准确地将气囊压力保持在0.7 ~ 2.1 PSI之间。与3.5分钟的目标相比,每个气囊组的充气持续时间的准确性为96.31%,并且对皮肤压力没有明显影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Raspberry Pi-based Decubitus Reducing Mattress with Air Pressure Monitoring System and Air Leaks Detector
Decubitus ulcers appear when the skin receives intense pressure for a short time or mild pressure for a longer time. Currently, nurses assist immobilized patients to change their position every 2 hours to avoid decubitus ulcers. Another option is using the pressure-reducing mattress. This mattress has the feature to change the pressure strength, but the air pressure and leakage are unknown. Both of these problems will be overcome by the automatic mattress developed in this study. The developed mattress uses gas pressure sensors, a Raspberry Pi, solenoid valves, and an AC air pump. The mattress pumping process is controlled based on the air pressure from 0.7 to 2.1 PSI in 3.5 minutes for each airbag group. The airbags are controlled to form wavelike contours with the feedback from the gas pressure sensors. A prolonged period to reach maximum pressure indicates the air leaks. The testing result shows that the control system can maintain the pressure of the airbag from 0.7 to 2.1 PSI accurately during the pumping process, with or without load on the mat. The accuracy of the pumping duration for each airbag group is 96.31% from the 3.5 minutes goal and gives no meaningful effect to skin pressure.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信