{"title":"谐波降频中过零变压器的研究","authors":"C. M. Hadzer, S. Masri, N. Mahamad","doi":"10.1109/PECON.2003.1437440","DOIUrl":null,"url":null,"abstract":"In this paper, a simple and practical approach to minimize the zero-sequence current harmonics in 3-phase 4-wire power distribution system is proposed. The zero-sequence current harmonic is minimized by using a very low zero-sequence impedance transformer. The very low zero-sequence impedance transformer is shunt connected to the load. Besides having very low zero-sequence impedance, this transformer also has very high both positive and negative sequence impedances. Thus, the zero-passing transformer has no effect on the positive and negative sequence harmonics. Because not all the harmonic can be reduced by zero-passing transformer, the LC filter is provided to cancel the entire harmonic. This LC filter is also shunt connected to the load. The dominant zero-sequence harmonic that is 3/sup rd/ harmonic current, which is generated by the load, will flow through the shunt load connected transformer and other harmonics current will flow through the LC filter. The practical excellency and validity of reduction technique are demonstrated experimentally.","PeriodicalId":136640,"journal":{"name":"Proceedings. National Power Engineering Conference, 2003. PECon 2003.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A study on zero-passing transformer in harmonics reduction\",\"authors\":\"C. M. Hadzer, S. Masri, N. Mahamad\",\"doi\":\"10.1109/PECON.2003.1437440\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a simple and practical approach to minimize the zero-sequence current harmonics in 3-phase 4-wire power distribution system is proposed. The zero-sequence current harmonic is minimized by using a very low zero-sequence impedance transformer. The very low zero-sequence impedance transformer is shunt connected to the load. Besides having very low zero-sequence impedance, this transformer also has very high both positive and negative sequence impedances. Thus, the zero-passing transformer has no effect on the positive and negative sequence harmonics. Because not all the harmonic can be reduced by zero-passing transformer, the LC filter is provided to cancel the entire harmonic. This LC filter is also shunt connected to the load. The dominant zero-sequence harmonic that is 3/sup rd/ harmonic current, which is generated by the load, will flow through the shunt load connected transformer and other harmonics current will flow through the LC filter. The practical excellency and validity of reduction technique are demonstrated experimentally.\",\"PeriodicalId\":136640,\"journal\":{\"name\":\"Proceedings. National Power Engineering Conference, 2003. PECon 2003.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings. National Power Engineering Conference, 2003. PECon 2003.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECON.2003.1437440\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. National Power Engineering Conference, 2003. PECon 2003.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECON.2003.1437440","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文提出了一种简单实用的减小三相四线制配电系统零序电流谐波的方法。采用极低的零序阻抗变压器,使零序电流谐波降到最低。极低的零序阻抗变压器并联连接到负载上。除了具有非常低的零序阻抗外,该变压器还具有非常高的正序和负序阻抗。因此,过零变压器对正、负序谐波没有影响。由于过零变压器并不能消除所有谐波,所以采用LC滤波器来抵消全部谐波。此LC滤波器也并联连接到负载上。负载产生的占主导地位的零序谐波为3/sup /谐波电流,将流经并联负载连接的变压器,其他谐波电流将流经LC滤波器。实验证明了该技术的实用性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A study on zero-passing transformer in harmonics reduction
In this paper, a simple and practical approach to minimize the zero-sequence current harmonics in 3-phase 4-wire power distribution system is proposed. The zero-sequence current harmonic is minimized by using a very low zero-sequence impedance transformer. The very low zero-sequence impedance transformer is shunt connected to the load. Besides having very low zero-sequence impedance, this transformer also has very high both positive and negative sequence impedances. Thus, the zero-passing transformer has no effect on the positive and negative sequence harmonics. Because not all the harmonic can be reduced by zero-passing transformer, the LC filter is provided to cancel the entire harmonic. This LC filter is also shunt connected to the load. The dominant zero-sequence harmonic that is 3/sup rd/ harmonic current, which is generated by the load, will flow through the shunt load connected transformer and other harmonics current will flow through the LC filter. The practical excellency and validity of reduction technique are demonstrated experimentally.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信