雪崩光电探测器在低温下的性能:MPPCs在低于77 K温度下的操作

A. Cardini, V. Fanti, A. Lai
{"title":"雪崩光电探测器在低温下的性能:MPPCs在低于77 K温度下的操作","authors":"A. Cardini, V. Fanti, A. Lai","doi":"10.1109/NSSMIC.2013.6829598","DOIUrl":null,"url":null,"abstract":"We are investigating the possibility of using Silicon Avalanche Photo Detectors (both in proportional and in Geiger mode) to readout inorganic scintillators operated at cryogenic temperatures. Such detectors, that need to operate close to LHe temperatures and in a magnetic field of a few Tesla, was proposed by our group as a way to built an active polarized target to be used for neutrino physics, for the searches of axions and CP violation, as suggested by some theoretical papers. In the present work we have investigated in some details the performance of Hamamatsu MPPCs down to LHe temperature, to verify the temperature range of usability of these devices. Measurement of the most important parameters will be presented: quantum efficiency, dark current, dark rate, gain. These results will be compared to what we measured on Large Area Silicon APDs operating in the same temperature range.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance of avalanche photodetectors at cryogenic temperatures: Operations of MPPCs at temperatures below 77 K\",\"authors\":\"A. Cardini, V. Fanti, A. Lai\",\"doi\":\"10.1109/NSSMIC.2013.6829598\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We are investigating the possibility of using Silicon Avalanche Photo Detectors (both in proportional and in Geiger mode) to readout inorganic scintillators operated at cryogenic temperatures. Such detectors, that need to operate close to LHe temperatures and in a magnetic field of a few Tesla, was proposed by our group as a way to built an active polarized target to be used for neutrino physics, for the searches of axions and CP violation, as suggested by some theoretical papers. In the present work we have investigated in some details the performance of Hamamatsu MPPCs down to LHe temperature, to verify the temperature range of usability of these devices. Measurement of the most important parameters will be presented: quantum efficiency, dark current, dark rate, gain. These results will be compared to what we measured on Large Area Silicon APDs operating in the same temperature range.\",\"PeriodicalId\":246351,\"journal\":{\"name\":\"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2013.6829598\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2013.6829598","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们正在研究使用硅雪崩光电探测器(比例和盖革模式)读取低温下运行的无机闪烁体的可能性。这种探测器需要在接近LHe温度和几特斯拉的磁场中工作,我们小组提出了一种方法,作为建立一个主动极化目标,用于中微子物理,用于搜索轴子和CP违和,正如一些理论论文所建议的那样。在本工作中,我们详细研究了滨松MPPCs在LHe温度下的性能,以验证这些器件的可用性温度范围。测量最重要的参数将被提出:量子效率,暗电流,暗速率,增益。这些结果将与我们在相同温度范围内工作的大面积硅apd上测量的结果进行比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance of avalanche photodetectors at cryogenic temperatures: Operations of MPPCs at temperatures below 77 K
We are investigating the possibility of using Silicon Avalanche Photo Detectors (both in proportional and in Geiger mode) to readout inorganic scintillators operated at cryogenic temperatures. Such detectors, that need to operate close to LHe temperatures and in a magnetic field of a few Tesla, was proposed by our group as a way to built an active polarized target to be used for neutrino physics, for the searches of axions and CP violation, as suggested by some theoretical papers. In the present work we have investigated in some details the performance of Hamamatsu MPPCs down to LHe temperature, to verify the temperature range of usability of these devices. Measurement of the most important parameters will be presented: quantum efficiency, dark current, dark rate, gain. These results will be compared to what we measured on Large Area Silicon APDs operating in the same temperature range.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信