拉曼分布式温度传感器的高精度热点尺寸估计技术

Luís C. B. Silva, C. E. Castellani, M. Segatto, M. Pontes
{"title":"拉曼分布式温度传感器的高精度热点尺寸估计技术","authors":"Luís C. B. Silva, C. E. Castellani, M. Segatto, M. Pontes","doi":"10.1109/IMOC43827.2019.9317584","DOIUrl":null,"url":null,"abstract":"We report in this work for the first time, to the best of the author’s knowledge, an approach that allows to accurately determine directly from the sensor response the hot spot size in Raman Distributed Temperature Sensors. Our method applies a linear regression model to the full width at half maximum response based on the correlation between the spatial and temperature measurements of the sensor. Measurements of hot spot sizes of only 5 cm were achieved with 98% precision for a commercial sensor with spatial resolution of 1 m. Moreover, for hot spots shorter than the sensor resolution this technique also allows improvements in the average accuracy of temperature measurements by up to 86%.","PeriodicalId":175865,"journal":{"name":"2019 SBMO/IEEE MTT-S International Microwave and Optoelectronics Conference (IMOC)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"High accuracy hot spot size estimation technique for Raman Distributed Temperature Sensors\",\"authors\":\"Luís C. B. Silva, C. E. Castellani, M. Segatto, M. Pontes\",\"doi\":\"10.1109/IMOC43827.2019.9317584\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We report in this work for the first time, to the best of the author’s knowledge, an approach that allows to accurately determine directly from the sensor response the hot spot size in Raman Distributed Temperature Sensors. Our method applies a linear regression model to the full width at half maximum response based on the correlation between the spatial and temperature measurements of the sensor. Measurements of hot spot sizes of only 5 cm were achieved with 98% precision for a commercial sensor with spatial resolution of 1 m. Moreover, for hot spots shorter than the sensor resolution this technique also allows improvements in the average accuracy of temperature measurements by up to 86%.\",\"PeriodicalId\":175865,\"journal\":{\"name\":\"2019 SBMO/IEEE MTT-S International Microwave and Optoelectronics Conference (IMOC)\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 SBMO/IEEE MTT-S International Microwave and Optoelectronics Conference (IMOC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMOC43827.2019.9317584\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 SBMO/IEEE MTT-S International Microwave and Optoelectronics Conference (IMOC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMOC43827.2019.9317584","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

据作者所知,我们在这项工作中首次报告了一种方法,该方法可以直接从传感器响应中准确确定拉曼分布式温度传感器中的热点大小。基于传感器的空间和温度测量值之间的相关性,我们的方法应用线性回归模型到最大响应的一半时的全宽度。对于空间分辨率为1米的商用传感器,仅测量5厘米大小的热点,精度达到98%。此外,对于比传感器分辨率短的热点,该技术还可以将温度测量的平均精度提高高达86%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
High accuracy hot spot size estimation technique for Raman Distributed Temperature Sensors
We report in this work for the first time, to the best of the author’s knowledge, an approach that allows to accurately determine directly from the sensor response the hot spot size in Raman Distributed Temperature Sensors. Our method applies a linear regression model to the full width at half maximum response based on the correlation between the spatial and temperature measurements of the sensor. Measurements of hot spot sizes of only 5 cm were achieved with 98% precision for a commercial sensor with spatial resolution of 1 m. Moreover, for hot spots shorter than the sensor resolution this technique also allows improvements in the average accuracy of temperature measurements by up to 86%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信