用于医疗植入物通信系统的可靠先听后说机制

S. Kulaç, H. Arslan
{"title":"用于医疗植入物通信系统的可靠先听后说机制","authors":"S. Kulaç, H. Arslan","doi":"10.1109/HealthCom.2016.7749531","DOIUrl":null,"url":null,"abstract":"Health care applications of wireless communication have been finding places dramatically. One of these applications is communication of implantable medical devices (IMD)s. It is expected that the number of IMDs will increase greatly in the near future. As a result, significant congestion will be experienced in medical implant communication service (MICS) band, leading to interference problems. In this study, we propose reliable listen-before-talk (LBT) mechanism at low signal-to-noise ratios (SNR)s for medical implant communication systems in order to mitigate the interference effects. In our method, we have just brought out power difference between mean peak and mean lowest power spectral values and it provides reliable and simple monitoring of MICS channels' occupation fastly. Our proposed method has superior performance when threshold power level is considered according to the federal communication commission (FCC) Part 95 regulatory standard.","PeriodicalId":167022,"journal":{"name":"2016 IEEE 18th International Conference on e-Health Networking, Applications and Services (Healthcom)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Reliable listen-before-talk mechanism for medical implant communication systems\",\"authors\":\"S. Kulaç, H. Arslan\",\"doi\":\"10.1109/HealthCom.2016.7749531\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Health care applications of wireless communication have been finding places dramatically. One of these applications is communication of implantable medical devices (IMD)s. It is expected that the number of IMDs will increase greatly in the near future. As a result, significant congestion will be experienced in medical implant communication service (MICS) band, leading to interference problems. In this study, we propose reliable listen-before-talk (LBT) mechanism at low signal-to-noise ratios (SNR)s for medical implant communication systems in order to mitigate the interference effects. In our method, we have just brought out power difference between mean peak and mean lowest power spectral values and it provides reliable and simple monitoring of MICS channels' occupation fastly. Our proposed method has superior performance when threshold power level is considered according to the federal communication commission (FCC) Part 95 regulatory standard.\",\"PeriodicalId\":167022,\"journal\":{\"name\":\"2016 IEEE 18th International Conference on e-Health Networking, Applications and Services (Healthcom)\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE 18th International Conference on e-Health Networking, Applications and Services (Healthcom)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HealthCom.2016.7749531\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 18th International Conference on e-Health Networking, Applications and Services (Healthcom)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HealthCom.2016.7749531","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

无线通信在医疗保健方面的应用已经得到了极大的发展。其中一个应用是植入式医疗设备(IMD)的通信。预计在不久的将来,imd的数量将大大增加。因此,医疗植入通信服务(MICS)频段将出现严重的拥塞,从而导致干扰问题。在本研究中,我们提出了一种可靠的低信噪比(SNR)下的先听后讲(LBT)机制,用于医疗植入物通信系统,以减轻干扰效应。在我们的方法中,我们只是得到了平均峰值和平均最低功率谱值之间的功率差,它提供了可靠和简单的快速监测MICS信道占用情况。根据美国联邦通信委员会(FCC)第95部分监管标准考虑阈值功率电平时,我们提出的方法具有优越的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reliable listen-before-talk mechanism for medical implant communication systems
Health care applications of wireless communication have been finding places dramatically. One of these applications is communication of implantable medical devices (IMD)s. It is expected that the number of IMDs will increase greatly in the near future. As a result, significant congestion will be experienced in medical implant communication service (MICS) band, leading to interference problems. In this study, we propose reliable listen-before-talk (LBT) mechanism at low signal-to-noise ratios (SNR)s for medical implant communication systems in order to mitigate the interference effects. In our method, we have just brought out power difference between mean peak and mean lowest power spectral values and it provides reliable and simple monitoring of MICS channels' occupation fastly. Our proposed method has superior performance when threshold power level is considered according to the federal communication commission (FCC) Part 95 regulatory standard.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信