使用直流电容的PV逆变器的虚拟惯性

E. Waffenschmidt, R. Hui
{"title":"使用直流电容的PV逆变器的虚拟惯性","authors":"E. Waffenschmidt, R. Hui","doi":"10.1109/EPE.2016.7695607","DOIUrl":null,"url":null,"abstract":"Soon, virtual inertia for grid control must be covered by photovoltaic inverters. It is suggested to use DC link capacitors for this task. This requires 5 W, 50 J and a capacitor size of about 200 cm3 per installed kW, corresponding to the size of single phase DC link capacitors. It is shown that the additional power ripple (and thus current ripple) is in the order of 0.1% and the voltage ripple of the intermediate voltage will typically remain between +/-3.6%. The related control can be easily extended by adding a voltage signal to the control voltage, which is proportional to the frequency deviation. Then, the existing controller inherently sets the required additional power fluctuation required for the virtual inertia function.","PeriodicalId":119358,"journal":{"name":"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"45","resultStr":"{\"title\":\"Virtual inertia with PV inverters using DC-link capacitors\",\"authors\":\"E. Waffenschmidt, R. Hui\",\"doi\":\"10.1109/EPE.2016.7695607\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Soon, virtual inertia for grid control must be covered by photovoltaic inverters. It is suggested to use DC link capacitors for this task. This requires 5 W, 50 J and a capacitor size of about 200 cm3 per installed kW, corresponding to the size of single phase DC link capacitors. It is shown that the additional power ripple (and thus current ripple) is in the order of 0.1% and the voltage ripple of the intermediate voltage will typically remain between +/-3.6%. The related control can be easily extended by adding a voltage signal to the control voltage, which is proportional to the frequency deviation. Then, the existing controller inherently sets the required additional power fluctuation required for the virtual inertia function.\",\"PeriodicalId\":119358,\"journal\":{\"name\":\"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"45\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE.2016.7695607\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE.2016.7695607","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 45

摘要

很快,光伏逆变器必须覆盖电网控制的虚拟惯性。建议使用直流链路电容。这需要5w, 50j,每安装kW的电容器尺寸约为200 cm3,对应于单相直流链路电容器的尺寸。结果表明,额外的功率纹波(以及电流纹波)约为0.1%,中间电压的电压纹波通常保持在+/-3.6%之间。通过在控制电压上添加与频率偏差成正比的电压信号,可以很容易地扩展相关控制。然后,现有控制器固有地设定了虚拟惯性函数所需的额外功率波动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Virtual inertia with PV inverters using DC-link capacitors
Soon, virtual inertia for grid control must be covered by photovoltaic inverters. It is suggested to use DC link capacitors for this task. This requires 5 W, 50 J and a capacitor size of about 200 cm3 per installed kW, corresponding to the size of single phase DC link capacitors. It is shown that the additional power ripple (and thus current ripple) is in the order of 0.1% and the voltage ripple of the intermediate voltage will typically remain between +/-3.6%. The related control can be easily extended by adding a voltage signal to the control voltage, which is proportional to the frequency deviation. Then, the existing controller inherently sets the required additional power fluctuation required for the virtual inertia function.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信