带监护系统的活塞驱动自动心肺复苏装置的设计

M. Alam, M. A. Amin, Mahamud Hussain, R. H. Bhuiyan, Mohammad Monirujjaman Khan
{"title":"带监护系统的活塞驱动自动心肺复苏装置的设计","authors":"M. Alam, M. A. Amin, Mahamud Hussain, R. H. Bhuiyan, Mohammad Monirujjaman Khan","doi":"10.1109/ICREST.2019.8644482","DOIUrl":null,"url":null,"abstract":"Cardiopulmonary Resuscitation (CPR) is an emergency medical procedure applied when a patient’s heart stops functioning suddenly, mainly due to cardiac arrest, drowning or electric shock. Normally, CPR is applied manually but the process is ineffective to provide adequate chest compressions to cardiac arrest patients. The main objective in this paper is to design a mechanized process of providing CPR and thus replacing the traditional manual CPR technique altogether. We designed an automated CPR device with piston-driven chest compression system and a patient monitoring system. The patient monitoring system consists of a heart rate monitor, body temperature monitor and respiratory rate monitor. The heart rate monitor is integrated with the automated CPR device. This means that when the heart rate monitor detects patient’s heart beat then the automated CPR device will not operate but if the heart rate monitor detects no heart beat then the automated CPR device will immediately provide CPR to the patient. The automated CPR along with the patient monitoring system has been tested on a CPR manikin and the results of the performance is well within the accepted CPR guidelines.","PeriodicalId":108842,"journal":{"name":"2019 International Conference on Robotics,Electrical and Signal Processing Techniques (ICREST)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Design of Piston-Driven Automated Cardiopulmonary Resuscitation Device with Patient Monitoring System\",\"authors\":\"M. Alam, M. A. Amin, Mahamud Hussain, R. H. Bhuiyan, Mohammad Monirujjaman Khan\",\"doi\":\"10.1109/ICREST.2019.8644482\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cardiopulmonary Resuscitation (CPR) is an emergency medical procedure applied when a patient’s heart stops functioning suddenly, mainly due to cardiac arrest, drowning or electric shock. Normally, CPR is applied manually but the process is ineffective to provide adequate chest compressions to cardiac arrest patients. The main objective in this paper is to design a mechanized process of providing CPR and thus replacing the traditional manual CPR technique altogether. We designed an automated CPR device with piston-driven chest compression system and a patient monitoring system. The patient monitoring system consists of a heart rate monitor, body temperature monitor and respiratory rate monitor. The heart rate monitor is integrated with the automated CPR device. This means that when the heart rate monitor detects patient’s heart beat then the automated CPR device will not operate but if the heart rate monitor detects no heart beat then the automated CPR device will immediately provide CPR to the patient. The automated CPR along with the patient monitoring system has been tested on a CPR manikin and the results of the performance is well within the accepted CPR guidelines.\",\"PeriodicalId\":108842,\"journal\":{\"name\":\"2019 International Conference on Robotics,Electrical and Signal Processing Techniques (ICREST)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Robotics,Electrical and Signal Processing Techniques (ICREST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICREST.2019.8644482\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Robotics,Electrical and Signal Processing Techniques (ICREST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICREST.2019.8644482","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

心肺复苏术(CPR)是一种紧急医疗程序,当病人的心脏突然停止运作,主要是由于心脏骤停,溺水或电击。通常情况下,心肺复苏术是手动实施的,但该过程无法为心脏骤停患者提供足够的胸部按压。本文的主要目的是设计一种提供心肺复苏术的机械化过程,从而完全取代传统的人工心肺复苏术。我们设计了一种带有活塞驱动胸外按压系统和病人监护系统的自动心肺复苏术装置。患者监护系统由心率监测仪、体温监测仪和呼吸频率监测仪组成。心率监测器与自动心肺复苏术装置集成在一起。这意味着当心率监测器检测到病人的心跳时,自动心肺复苏术设备将不会操作,但如果心率监测器检测到没有心跳,那么自动心肺复苏术设备将立即为病人提供心肺复苏术。自动心肺复苏术和病人监测系统已经在一个心肺复苏术人体模型上进行了测试,其性能结果完全符合公认的心肺复苏术指导方针。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of Piston-Driven Automated Cardiopulmonary Resuscitation Device with Patient Monitoring System
Cardiopulmonary Resuscitation (CPR) is an emergency medical procedure applied when a patient’s heart stops functioning suddenly, mainly due to cardiac arrest, drowning or electric shock. Normally, CPR is applied manually but the process is ineffective to provide adequate chest compressions to cardiac arrest patients. The main objective in this paper is to design a mechanized process of providing CPR and thus replacing the traditional manual CPR technique altogether. We designed an automated CPR device with piston-driven chest compression system and a patient monitoring system. The patient monitoring system consists of a heart rate monitor, body temperature monitor and respiratory rate monitor. The heart rate monitor is integrated with the automated CPR device. This means that when the heart rate monitor detects patient’s heart beat then the automated CPR device will not operate but if the heart rate monitor detects no heart beat then the automated CPR device will immediately provide CPR to the patient. The automated CPR along with the patient monitoring system has been tested on a CPR manikin and the results of the performance is well within the accepted CPR guidelines.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信