{"title":"混合振动柱消能杆合理面积的研究","authors":"Zehua Bao, Xueqi Zhong, Jianzhong Li","doi":"10.2749/ghent.2021.1407","DOIUrl":null,"url":null,"abstract":"In recent years, hybrid rocking columns have drawn more and more interests from researchers, due to their self-centering capacity. The energy-dissipation bars, which are generally applied at the rocking joints of hybrid rocking columns, could improve their energy dissipation capacities. Thus, the reasonable reinforcement ratio of energy-dissipation bars is much required for engineering applications. To determine the reasonable reinforcement ratio of energy-dissipation bars, a numerical investigation is conducted in this paper based on nonlinear time-history analysis. The analysis results show that a reasonable reinforcement ratio of energy-dissipation bars can effectively reduce seismic displacements of the hybrid rocking columns, without excessive residual deformations. Further, the reasonable reinforcement ratio of energy-dissipation bars for hybrid rocking columns with different periods is proposed in this paper.","PeriodicalId":162435,"journal":{"name":"IABSE Congress, Ghent 2021: Structural Engineering for Future Societal Needs","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation on the reasonable area of energy-dissipation bars for hybrid rocking columns\",\"authors\":\"Zehua Bao, Xueqi Zhong, Jianzhong Li\",\"doi\":\"10.2749/ghent.2021.1407\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In recent years, hybrid rocking columns have drawn more and more interests from researchers, due to their self-centering capacity. The energy-dissipation bars, which are generally applied at the rocking joints of hybrid rocking columns, could improve their energy dissipation capacities. Thus, the reasonable reinforcement ratio of energy-dissipation bars is much required for engineering applications. To determine the reasonable reinforcement ratio of energy-dissipation bars, a numerical investigation is conducted in this paper based on nonlinear time-history analysis. The analysis results show that a reasonable reinforcement ratio of energy-dissipation bars can effectively reduce seismic displacements of the hybrid rocking columns, without excessive residual deformations. Further, the reasonable reinforcement ratio of energy-dissipation bars for hybrid rocking columns with different periods is proposed in this paper.\",\"PeriodicalId\":162435,\"journal\":{\"name\":\"IABSE Congress, Ghent 2021: Structural Engineering for Future Societal Needs\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IABSE Congress, Ghent 2021: Structural Engineering for Future Societal Needs\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2749/ghent.2021.1407\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IABSE Congress, Ghent 2021: Structural Engineering for Future Societal Needs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2749/ghent.2021.1407","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Investigation on the reasonable area of energy-dissipation bars for hybrid rocking columns
In recent years, hybrid rocking columns have drawn more and more interests from researchers, due to their self-centering capacity. The energy-dissipation bars, which are generally applied at the rocking joints of hybrid rocking columns, could improve their energy dissipation capacities. Thus, the reasonable reinforcement ratio of energy-dissipation bars is much required for engineering applications. To determine the reasonable reinforcement ratio of energy-dissipation bars, a numerical investigation is conducted in this paper based on nonlinear time-history analysis. The analysis results show that a reasonable reinforcement ratio of energy-dissipation bars can effectively reduce seismic displacements of the hybrid rocking columns, without excessive residual deformations. Further, the reasonable reinforcement ratio of energy-dissipation bars for hybrid rocking columns with different periods is proposed in this paper.