{"title":"高压斩波器,用于电力牵引应用,采用大型GTO晶闸管串联连接","authors":"S. Saadate, R. Le Doeuff, R. Périot","doi":"10.1109/IECON.1989.69631","DOIUrl":null,"url":null,"abstract":"The authors present considerations for the series connection of GTOs (gate turn-off thyristors). Criteria for the selection of GTOs, design of snubbers, and adoption of GTO control are given. The advantages and drawbacks of the strategies used are discussed. Detailed experimental results concerning the GTO commutations and the snubber circuit are presented. The influence of important parameters, such as the load current, on the transient and steady-state voltage distribution on the GTOs is discussed. As series connection of GTOs is liable to be used in the high-voltage static converters utilized in rail traction systems, two industrial realizations are considered.<<ETX>>","PeriodicalId":384081,"journal":{"name":"15th Annual Conference of IEEE Industrial Electronics Society","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"High voltage, chopper for electrical traction applications using series connection of large GTO thyristors\",\"authors\":\"S. Saadate, R. Le Doeuff, R. Périot\",\"doi\":\"10.1109/IECON.1989.69631\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors present considerations for the series connection of GTOs (gate turn-off thyristors). Criteria for the selection of GTOs, design of snubbers, and adoption of GTO control are given. The advantages and drawbacks of the strategies used are discussed. Detailed experimental results concerning the GTO commutations and the snubber circuit are presented. The influence of important parameters, such as the load current, on the transient and steady-state voltage distribution on the GTOs is discussed. As series connection of GTOs is liable to be used in the high-voltage static converters utilized in rail traction systems, two industrial realizations are considered.<<ETX>>\",\"PeriodicalId\":384081,\"journal\":{\"name\":\"15th Annual Conference of IEEE Industrial Electronics Society\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"15th Annual Conference of IEEE Industrial Electronics Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.1989.69631\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"15th Annual Conference of IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.1989.69631","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
High voltage, chopper for electrical traction applications using series connection of large GTO thyristors
The authors present considerations for the series connection of GTOs (gate turn-off thyristors). Criteria for the selection of GTOs, design of snubbers, and adoption of GTO control are given. The advantages and drawbacks of the strategies used are discussed. Detailed experimental results concerning the GTO commutations and the snubber circuit are presented. The influence of important parameters, such as the load current, on the transient and steady-state voltage distribution on the GTOs is discussed. As series connection of GTOs is liable to be used in the high-voltage static converters utilized in rail traction systems, two industrial realizations are considered.<>