印度尼西亚万隆“X”医院高护病房(HCU)的声学分析

Febi Rhiana, J. Sarwono, F. Soelami
{"title":"印度尼西亚万隆“X”医院高护病房(HCU)的声学分析","authors":"Febi Rhiana, J. Sarwono, F. Soelami","doi":"10.1109/ICICI-BME.2011.6108594","DOIUrl":null,"url":null,"abstract":"Acoustical comfort in a hospital is utterly needed for improving patient's recovery progress, quality of sleep, and also working quality of medical staff. A research in the study of acoustical comfort was carried out in High Care Unit (HCU) at Hospital “X”, Bandung, Indonesia. Three parameters measured and modified in this research are definition 50 (D-50), sound pressure level (SPL), and reverberation time (T-30) through simulation, actual measurement, subjective observation, and passive acoustic recommendation methods.","PeriodicalId":395673,"journal":{"name":"2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering","volume":"71 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Acoustic analysis of High Care Unit (HCU) at hospital “X” in Bandung, Indonesia\",\"authors\":\"Febi Rhiana, J. Sarwono, F. Soelami\",\"doi\":\"10.1109/ICICI-BME.2011.6108594\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Acoustical comfort in a hospital is utterly needed for improving patient's recovery progress, quality of sleep, and also working quality of medical staff. A research in the study of acoustical comfort was carried out in High Care Unit (HCU) at Hospital “X”, Bandung, Indonesia. Three parameters measured and modified in this research are definition 50 (D-50), sound pressure level (SPL), and reverberation time (T-30) through simulation, actual measurement, subjective observation, and passive acoustic recommendation methods.\",\"PeriodicalId\":395673,\"journal\":{\"name\":\"2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering\",\"volume\":\"71 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICICI-BME.2011.6108594\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICICI-BME.2011.6108594","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

医院的声舒适对于提高患者的康复进度、睡眠质量以及医护人员的工作质量都是必不可少的。在印度尼西亚万隆“X”医院的高级护理病房(HCU)进行了一项声学舒适性研究。本研究通过仿真、实际测量、主观观察和被动声学推荐等方法测量并修改了定义50 (D-50)、声压级(SPL)和混响时间(T-30)三个参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Acoustic analysis of High Care Unit (HCU) at hospital “X” in Bandung, Indonesia
Acoustical comfort in a hospital is utterly needed for improving patient's recovery progress, quality of sleep, and also working quality of medical staff. A research in the study of acoustical comfort was carried out in High Care Unit (HCU) at Hospital “X”, Bandung, Indonesia. Three parameters measured and modified in this research are definition 50 (D-50), sound pressure level (SPL), and reverberation time (T-30) through simulation, actual measurement, subjective observation, and passive acoustic recommendation methods.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信