用AMI和变压器测量建立和验证二次电路模型

J. Peppanen, S. Grijalva, M. Reno, R. Broderick
{"title":"用AMI和变压器测量建立和验证二次电路模型","authors":"J. Peppanen, S. Grijalva, M. Reno, R. Broderick","doi":"10.1109/NAPS.2016.7747867","DOIUrl":null,"url":null,"abstract":"Accurate distribution secondary circuit models are needed to effectively monitor and coordinate the distributed energy resources located in the secondary circuits and to enhance overall distribution system operations and planning. Accurate secondary models are also needed to fully leverage the measurement data received from smart meters and distributed energy resources at the customer premises. This paper discusses approaches for creating distribution system secondary low-voltage circuit models utilizing smart meter measurements. This paper also discusses methods to model secondary circuits when the loads and distributed energy resources are only partially metered. The presented methods are demonstrated on a real distribution secondary circuit with smart meter measurements and transformer low voltage measurements. Practical challenges related to real measurement data are discussed.","PeriodicalId":249041,"journal":{"name":"2016 North American Power Symposium (NAPS)","volume":"1990 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Secondary circuit model creation and validation with AMI and transformer measurements\",\"authors\":\"J. Peppanen, S. Grijalva, M. Reno, R. Broderick\",\"doi\":\"10.1109/NAPS.2016.7747867\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Accurate distribution secondary circuit models are needed to effectively monitor and coordinate the distributed energy resources located in the secondary circuits and to enhance overall distribution system operations and planning. Accurate secondary models are also needed to fully leverage the measurement data received from smart meters and distributed energy resources at the customer premises. This paper discusses approaches for creating distribution system secondary low-voltage circuit models utilizing smart meter measurements. This paper also discusses methods to model secondary circuits when the loads and distributed energy resources are only partially metered. The presented methods are demonstrated on a real distribution secondary circuit with smart meter measurements and transformer low voltage measurements. Practical challenges related to real measurement data are discussed.\",\"PeriodicalId\":249041,\"journal\":{\"name\":\"2016 North American Power Symposium (NAPS)\",\"volume\":\"1990 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 North American Power Symposium (NAPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAPS.2016.7747867\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 North American Power Symposium (NAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.2016.7747867","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

为了有效地监测和协调分布在配电二次回路中的分布式能源,提高配电系统的整体运行和规划水平,需要精确的配电二次回路模型。还需要精确的二次模型来充分利用从智能电表和客户场所的分布式能源接收到的测量数据。本文讨论了利用智能电表测量创建配电系统二次低压电路模型的方法。本文还讨论了负荷和分布式能源仅部分计量时二次回路的建模方法。在实际配电二次回路中进行了智能电表测量和变压器低压测量。讨论了与实际测量数据相关的实际挑战。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Secondary circuit model creation and validation with AMI and transformer measurements
Accurate distribution secondary circuit models are needed to effectively monitor and coordinate the distributed energy resources located in the secondary circuits and to enhance overall distribution system operations and planning. Accurate secondary models are also needed to fully leverage the measurement data received from smart meters and distributed energy resources at the customer premises. This paper discusses approaches for creating distribution system secondary low-voltage circuit models utilizing smart meter measurements. This paper also discusses methods to model secondary circuits when the loads and distributed energy resources are only partially metered. The presented methods are demonstrated on a real distribution secondary circuit with smart meter measurements and transformer low voltage measurements. Practical challenges related to real measurement data are discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信