{"title":"用电容式传感器测量轴位移","authors":"Tomas Pawlenka, J. Škuta","doi":"10.1109/ICCC51557.2021.9454656","DOIUrl":null,"url":null,"abstract":"The paper is focused on shaft displacement measurement with the use of capacitive sensors made by printed circuit technology. A basis is a measuring unit with a capacitive-digital converter (CDC), which can provide the measured data to the main microcontroller for their processing and storage. The main goal was to design a low-cost solution for measuring the position of the shaft, which would be able to compete with professional and expensive units. Therefore, the result of this work is also a comparison of measured data with data from the professional unit and sensors from the Micro-Epsilon company. This unit also served as a calibration device. Thanks to this device, it was possible to convert the resulting signal representing capacity to the displacement in micrometres.","PeriodicalId":339049,"journal":{"name":"2021 22nd International Carpathian Control Conference (ICCC)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Shaft Displacement Measurement Using Capacitive Sensors\",\"authors\":\"Tomas Pawlenka, J. Škuta\",\"doi\":\"10.1109/ICCC51557.2021.9454656\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper is focused on shaft displacement measurement with the use of capacitive sensors made by printed circuit technology. A basis is a measuring unit with a capacitive-digital converter (CDC), which can provide the measured data to the main microcontroller for their processing and storage. The main goal was to design a low-cost solution for measuring the position of the shaft, which would be able to compete with professional and expensive units. Therefore, the result of this work is also a comparison of measured data with data from the professional unit and sensors from the Micro-Epsilon company. This unit also served as a calibration device. Thanks to this device, it was possible to convert the resulting signal representing capacity to the displacement in micrometres.\",\"PeriodicalId\":339049,\"journal\":{\"name\":\"2021 22nd International Carpathian Control Conference (ICCC)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 22nd International Carpathian Control Conference (ICCC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCC51557.2021.9454656\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 22nd International Carpathian Control Conference (ICCC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCC51557.2021.9454656","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Shaft Displacement Measurement Using Capacitive Sensors
The paper is focused on shaft displacement measurement with the use of capacitive sensors made by printed circuit technology. A basis is a measuring unit with a capacitive-digital converter (CDC), which can provide the measured data to the main microcontroller for their processing and storage. The main goal was to design a low-cost solution for measuring the position of the shaft, which would be able to compete with professional and expensive units. Therefore, the result of this work is also a comparison of measured data with data from the professional unit and sensors from the Micro-Epsilon company. This unit also served as a calibration device. Thanks to this device, it was possible to convert the resulting signal representing capacity to the displacement in micrometres.