四家不同制造商的进气过滤器元件现场和实验室测试

S. Ingistov, J. Kohn
{"title":"四家不同制造商的进气过滤器元件现场和实验室测试","authors":"S. Ingistov, J. Kohn","doi":"10.1115/GT2018-75428","DOIUrl":null,"url":null,"abstract":"This Paper describes three-month onsite testing utilizing travelling laboratory furnished with four dedicated air ducts and required instrumentation needed to determine efficiency of filtration for submicron size particles. It also describes the subsequent testing of seasoned filters in offsite Laboratory furnished with instrumentation and equipment to conduct the dry and wet tests on previously Watson-field tested filters.\n The opportunity to simultaneously test four different IAFE, provided by four different Manufacturers, was unique and helpful in discerning the differences between these filters.","PeriodicalId":131179,"journal":{"name":"Volume 3: Coal, Biomass, and Alternative Fuels; Cycle Innovations; Electric Power; Industrial and Cogeneration; Organic Rankine Cycle Power Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Inlet Air Filter Elements Site and Laboratory Tests of Four Different Manufacturers\",\"authors\":\"S. Ingistov, J. Kohn\",\"doi\":\"10.1115/GT2018-75428\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This Paper describes three-month onsite testing utilizing travelling laboratory furnished with four dedicated air ducts and required instrumentation needed to determine efficiency of filtration for submicron size particles. It also describes the subsequent testing of seasoned filters in offsite Laboratory furnished with instrumentation and equipment to conduct the dry and wet tests on previously Watson-field tested filters.\\n The opportunity to simultaneously test four different IAFE, provided by four different Manufacturers, was unique and helpful in discerning the differences between these filters.\",\"PeriodicalId\":131179,\"journal\":{\"name\":\"Volume 3: Coal, Biomass, and Alternative Fuels; Cycle Innovations; Electric Power; Industrial and Cogeneration; Organic Rankine Cycle Power Systems\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 3: Coal, Biomass, and Alternative Fuels; Cycle Innovations; Electric Power; Industrial and Cogeneration; Organic Rankine Cycle Power Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/GT2018-75428\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 3: Coal, Biomass, and Alternative Fuels; Cycle Innovations; Electric Power; Industrial and Cogeneration; Organic Rankine Cycle Power Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/GT2018-75428","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文描述了三个月的现场测试,利用配备了四个专用风管的旅行实验室和所需的仪器来确定亚微米大小颗粒的过滤效率。它还描述了随后在配备仪器和设备的场外实验室中对经验丰富的过滤器进行的测试,以便对先前经过沃森现场测试的过滤器进行干湿测试。同时测试四种不同IAFE的机会,由四个不同的制造商提供,是独特的,有助于辨别这些过滤器之间的差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Inlet Air Filter Elements Site and Laboratory Tests of Four Different Manufacturers
This Paper describes three-month onsite testing utilizing travelling laboratory furnished with four dedicated air ducts and required instrumentation needed to determine efficiency of filtration for submicron size particles. It also describes the subsequent testing of seasoned filters in offsite Laboratory furnished with instrumentation and equipment to conduct the dry and wet tests on previously Watson-field tested filters. The opportunity to simultaneously test four different IAFE, provided by four different Manufacturers, was unique and helpful in discerning the differences between these filters.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信