{"title":"基于磷酸钼配合物的电化学微传感器快速测定水中总磷","authors":"Yin Bai, J. Tong, C. Bian, S. Xia","doi":"10.1109/NEMS.2013.6559678","DOIUrl":null,"url":null,"abstract":"This work mainly describes an electrochemical microsensor based on the reduction of molybdophosphate complex for fast determination of total phosphorus (TP) in water. Compared with the traditional methods for phosphate detection reported previously that used bulk electrodes, this microsensor responds faster, and can be applied to TP detection rather than merely phosphate. Calibration of phosphate has been performed with standard solutions prepared with KH2PO4 with pH adjusted to 1.0. The limit of detection (LOD) is 0.66 μmol/L, and linear range is 1~500 μmol/L. The sensitivity is -0.657 nA per μmol/L (R2=0.994). Detection of TP was also carried out in digested TP standard solutions, and the results were consistent with the nominal value of phosphorus concentration.","PeriodicalId":308928,"journal":{"name":"The 8th Annual IEEE International Conference on Nano/Micro Engineered and Molecular Systems","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"An electrochemical microsensor based on molybdophosphate complex for fast determination of total phosphorus in water\",\"authors\":\"Yin Bai, J. Tong, C. Bian, S. Xia\",\"doi\":\"10.1109/NEMS.2013.6559678\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work mainly describes an electrochemical microsensor based on the reduction of molybdophosphate complex for fast determination of total phosphorus (TP) in water. Compared with the traditional methods for phosphate detection reported previously that used bulk electrodes, this microsensor responds faster, and can be applied to TP detection rather than merely phosphate. Calibration of phosphate has been performed with standard solutions prepared with KH2PO4 with pH adjusted to 1.0. The limit of detection (LOD) is 0.66 μmol/L, and linear range is 1~500 μmol/L. The sensitivity is -0.657 nA per μmol/L (R2=0.994). Detection of TP was also carried out in digested TP standard solutions, and the results were consistent with the nominal value of phosphorus concentration.\",\"PeriodicalId\":308928,\"journal\":{\"name\":\"The 8th Annual IEEE International Conference on Nano/Micro Engineered and Molecular Systems\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The 8th Annual IEEE International Conference on Nano/Micro Engineered and Molecular Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEMS.2013.6559678\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 8th Annual IEEE International Conference on Nano/Micro Engineered and Molecular Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEMS.2013.6559678","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
摘要
本文主要介绍了一种基于磷酸钼配合物还原的电化学微传感器,用于水中总磷的快速测定。与之前报道的使用体电极的传统磷酸盐检测方法相比,该微传感器响应速度更快,可用于TP检测而不仅仅是磷酸盐检测。用pH调至1.0的KH2PO4配制的标准溶液对磷酸盐进行校准。检出限为0.66 μmol/L,线性范围为1~500 μmol/L。灵敏度为-0.657 nA / μmol/L (R2=0.994)。对消解后的TP标准溶液进行了TP检测,结果与标称的磷浓度值一致。
An electrochemical microsensor based on molybdophosphate complex for fast determination of total phosphorus in water
This work mainly describes an electrochemical microsensor based on the reduction of molybdophosphate complex for fast determination of total phosphorus (TP) in water. Compared with the traditional methods for phosphate detection reported previously that used bulk electrodes, this microsensor responds faster, and can be applied to TP detection rather than merely phosphate. Calibration of phosphate has been performed with standard solutions prepared with KH2PO4 with pH adjusted to 1.0. The limit of detection (LOD) is 0.66 μmol/L, and linear range is 1~500 μmol/L. The sensitivity is -0.657 nA per μmol/L (R2=0.994). Detection of TP was also carried out in digested TP standard solutions, and the results were consistent with the nominal value of phosphorus concentration.