{"title":"张滨风电场并网暂态分析","authors":"Li Wang, M. Hsieh, Shun-Chin Ke","doi":"10.1109/CACS.2013.6734177","DOIUrl":null,"url":null,"abstract":"This paper presents the transient simulated results of a three-phase short-circuit fault applied to one of the feeders of Jang-Bin wind farm connected to Taipower grid using a commercial power-system simulation software of PSS/E. The simulated transient voltage fluctuations, power variations, and frequency changes can serve as an operation reference for a power system connected with large-scale wind farms. It can also serve as a reference for the future development of Taiwan's offshore wind farms.","PeriodicalId":186492,"journal":{"name":"2013 CACS International Automatic Control Conference (CACS)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Transient analysis of Jang-Bin wind farm connected to Taipower grid\",\"authors\":\"Li Wang, M. Hsieh, Shun-Chin Ke\",\"doi\":\"10.1109/CACS.2013.6734177\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the transient simulated results of a three-phase short-circuit fault applied to one of the feeders of Jang-Bin wind farm connected to Taipower grid using a commercial power-system simulation software of PSS/E. The simulated transient voltage fluctuations, power variations, and frequency changes can serve as an operation reference for a power system connected with large-scale wind farms. It can also serve as a reference for the future development of Taiwan's offshore wind farms.\",\"PeriodicalId\":186492,\"journal\":{\"name\":\"2013 CACS International Automatic Control Conference (CACS)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 CACS International Automatic Control Conference (CACS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CACS.2013.6734177\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 CACS International Automatic Control Conference (CACS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CACS.2013.6734177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Transient analysis of Jang-Bin wind farm connected to Taipower grid
This paper presents the transient simulated results of a three-phase short-circuit fault applied to one of the feeders of Jang-Bin wind farm connected to Taipower grid using a commercial power-system simulation software of PSS/E. The simulated transient voltage fluctuations, power variations, and frequency changes can serve as an operation reference for a power system connected with large-scale wind farms. It can also serve as a reference for the future development of Taiwan's offshore wind farms.