医用ALPIDE像素检测器的光子抑制研究

F. Colamaria, G. Trombetta, G. Bruno, G. Robertis, V. Manzari, A. Mazzone, C. Pastore
{"title":"医用ALPIDE像素检测器的光子抑制研究","authors":"F. Colamaria, G. Trombetta, G. Bruno, G. Robertis, V. Manzari, A. Mazzone, C. Pastore","doi":"10.1109/IWASI.2019.8791306","DOIUrl":null,"url":null,"abstract":"The ALPIDE silicon pixel detector, designed for the upgrade of the ALICE Inner Tracking System at the CERN LHC, is potentially well suited also for usage in other fields, as for medical applications. In particular, it could provide excellent capabilities as detecting probe for radioguided surgery in oncology, in association to positron-emitting radiotracers. In this respect, to quantify the expected performance it is crucial to measure the sensitivity to low-energy photons, which constitute the main background for revealing the positron radiation. Due to its thin epitaxial sensitive layer, the ALPIDE is expected to be almost insensitive to photons. A measurement of the ALPIDE efficiency for the detection of 662 keV photons, emitted by a Cs-137 radioactive source, is reported in this paper. A value of 0.089%, with a relative uncertainty of 20%, was obtained, granting an excellent rejection of low-energy photons compared to other proposed devices.","PeriodicalId":330672,"journal":{"name":"2019 IEEE 8th International Workshop on Advances in Sensors and Interfaces (IWASI)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study of the photon rejection of the ALPIDE pixel detector for medical applications\",\"authors\":\"F. Colamaria, G. Trombetta, G. Bruno, G. Robertis, V. Manzari, A. Mazzone, C. Pastore\",\"doi\":\"10.1109/IWASI.2019.8791306\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The ALPIDE silicon pixel detector, designed for the upgrade of the ALICE Inner Tracking System at the CERN LHC, is potentially well suited also for usage in other fields, as for medical applications. In particular, it could provide excellent capabilities as detecting probe for radioguided surgery in oncology, in association to positron-emitting radiotracers. In this respect, to quantify the expected performance it is crucial to measure the sensitivity to low-energy photons, which constitute the main background for revealing the positron radiation. Due to its thin epitaxial sensitive layer, the ALPIDE is expected to be almost insensitive to photons. A measurement of the ALPIDE efficiency for the detection of 662 keV photons, emitted by a Cs-137 radioactive source, is reported in this paper. A value of 0.089%, with a relative uncertainty of 20%, was obtained, granting an excellent rejection of low-energy photons compared to other proposed devices.\",\"PeriodicalId\":330672,\"journal\":{\"name\":\"2019 IEEE 8th International Workshop on Advances in Sensors and Interfaces (IWASI)\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE 8th International Workshop on Advances in Sensors and Interfaces (IWASI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IWASI.2019.8791306\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 8th International Workshop on Advances in Sensors and Interfaces (IWASI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWASI.2019.8791306","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

ALPIDE硅像素探测器是为升级欧洲核子研究中心(CERN)大型强子对撞机(LHC)的ALICE内部跟踪系统而设计的,它也可能非常适合用于其他领域,如医疗应用。特别是与正电子放射示踪剂结合,可作为肿瘤放射引导手术的探测探针。在这方面,为了量化预期的性能,测量低能光子的灵敏度是至关重要的,低能光子构成了揭示正电子辐射的主要背景。由于其薄外延敏感层,预计ALPIDE对光子几乎不敏感。本文报道了一种用于检测铯-137放射源发射的662 keV光子的ALPIDE效率的测量。得到了0.089%的值,相对不确定度为20%,与其他提出的器件相比,可以很好地抑制低能光子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study of the photon rejection of the ALPIDE pixel detector for medical applications
The ALPIDE silicon pixel detector, designed for the upgrade of the ALICE Inner Tracking System at the CERN LHC, is potentially well suited also for usage in other fields, as for medical applications. In particular, it could provide excellent capabilities as detecting probe for radioguided surgery in oncology, in association to positron-emitting radiotracers. In this respect, to quantify the expected performance it is crucial to measure the sensitivity to low-energy photons, which constitute the main background for revealing the positron radiation. Due to its thin epitaxial sensitive layer, the ALPIDE is expected to be almost insensitive to photons. A measurement of the ALPIDE efficiency for the detection of 662 keV photons, emitted by a Cs-137 radioactive source, is reported in this paper. A value of 0.089%, with a relative uncertainty of 20%, was obtained, granting an excellent rejection of low-energy photons compared to other proposed devices.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信