{"title":"矩阵铅笔法在两相流条件下科里奥利质量流量计信号处理","authors":"O. Ibryaeva, D. Salov","doi":"10.1109/ICIEAM.2017.8076363","DOIUrl":null,"url":null,"abstract":"The paper investigates the possible applications of the Matrix Pencil Method in Coriolis mass flow meter signal processing. This method provides fast dynamic response since it requires only about one period of the sampled signal. Simulations results show that the proposed technique provides a better performance of frequency and phase difference tracking compared with the Hilbert Transform.","PeriodicalId":428982,"journal":{"name":"2017 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Matrix pencil method for coriolis mass flow meter signal processing in two-phase flow conditions\",\"authors\":\"O. Ibryaeva, D. Salov\",\"doi\":\"10.1109/ICIEAM.2017.8076363\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper investigates the possible applications of the Matrix Pencil Method in Coriolis mass flow meter signal processing. This method provides fast dynamic response since it requires only about one period of the sampled signal. Simulations results show that the proposed technique provides a better performance of frequency and phase difference tracking compared with the Hilbert Transform.\",\"PeriodicalId\":428982,\"journal\":{\"name\":\"2017 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIEAM.2017.8076363\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEAM.2017.8076363","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Matrix pencil method for coriolis mass flow meter signal processing in two-phase flow conditions
The paper investigates the possible applications of the Matrix Pencil Method in Coriolis mass flow meter signal processing. This method provides fast dynamic response since it requires only about one period of the sampled signal. Simulations results show that the proposed technique provides a better performance of frequency and phase difference tracking compared with the Hilbert Transform.