{"title":"从低压用户的角度看谐波阻抗中包含负载阻抗的不确定性","authors":"N. Nakhodchi, M. Bollen","doi":"10.1109/ICHQP53011.2022.9808615","DOIUrl":null,"url":null,"abstract":"This paper presents the impact of load impedance uncertainty on harmonic source and transfer impedance and consequently on harmonic propagation in distribution networks. A generic MV/LV model of the network and a more detailed model of an existing network are used. Both models include MV network and remote LV customers. Utilizing a Monte Carlo simulation method, it is shown that variation in load impedance has a big impact on the main resonant frequency of the local network but only limited influence on resonant frequency caused by remote loads connected to other LV networks.","PeriodicalId":249133,"journal":{"name":"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Including Load Impedance Uncertainty in Harmonic Impedance Seen from a Low-voltage Customer\",\"authors\":\"N. Nakhodchi, M. Bollen\",\"doi\":\"10.1109/ICHQP53011.2022.9808615\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the impact of load impedance uncertainty on harmonic source and transfer impedance and consequently on harmonic propagation in distribution networks. A generic MV/LV model of the network and a more detailed model of an existing network are used. Both models include MV network and remote LV customers. Utilizing a Monte Carlo simulation method, it is shown that variation in load impedance has a big impact on the main resonant frequency of the local network but only limited influence on resonant frequency caused by remote loads connected to other LV networks.\",\"PeriodicalId\":249133,\"journal\":{\"name\":\"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP53011.2022.9808615\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP53011.2022.9808615","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Including Load Impedance Uncertainty in Harmonic Impedance Seen from a Low-voltage Customer
This paper presents the impact of load impedance uncertainty on harmonic source and transfer impedance and consequently on harmonic propagation in distribution networks. A generic MV/LV model of the network and a more detailed model of an existing network are used. Both models include MV network and remote LV customers. Utilizing a Monte Carlo simulation method, it is shown that variation in load impedance has a big impact on the main resonant frequency of the local network but only limited influence on resonant frequency caused by remote loads connected to other LV networks.