R. M. Fleming, M. Fleming, T. Chaudhuri, A. McKusick, W. Dooley, Charles Glover
{"title":"使用FMTVDM可以直接从心肌灌注成像(MPI)中得出百分比直径狭窄(%DS)和冠状动脉血流储备(CFR)©©and Measurement of Isotope Redistribution","authors":"R. M. Fleming, M. Fleming, T. Chaudhuri, A. McKusick, W. Dooley, Charles Glover","doi":"10.4172/2155-9619.1000353","DOIUrl":null,"url":null,"abstract":"Background: Scientifically published studies have demonstrated that all isotopes, including Sestamibi redistribute. Measurement of this redistribution using FMTVDM©℗ provides an accurate method for determining wash-in and washout. Methods: Using FMTVDM©℗ 1040 human coronary arteries were studied to determine their wash-in and washout redistribution measured on a pixel-by-pixel basis. From FMTVDM©℗ the percent diameter stenosis (%DS) for each artery was determined. This %DS was then used to calculate coronary flow reserve (Calculated SFR) using a proprietary quadratic equation (QCFR©, FCFR©) previously derived from quantitative coronary arteriography (QCA) measurements. These calculated CFR values were then compared with the actual measured CFR obtained directly from QCA. Results: The results of the calculated CFR from FMTVDM©℗ with that obtained by direct QCA measurement showed a regression analysis of y= (0.8758•x)+0.4291, where y=the QCFR© and x=the QCA measured CFR. The R2 value (coefficient of determination) for this demonstrated a strong relationship at 0.87582. Conclusions: The use of the FMTVDM©℗ for measurement of isotope redistribution, including Sestamibi, provides an accurate quantitative method for determining both redistribution wash-in and redistribution washout, from which %DS can be calculated on a pixel-by-pixel basis. This %DS can then be used with the proprietary equation (QCFR©, FCFR©) to calculate the CFR directly from the MPI result using FMTVDM©℗. The implementation of this power tool, will provide for additional determination of the physiological effect of CAD without requiring additional QCA equipment and expertise costs, making QCFR© possible in most if not all hospitals with nuclear medicine departments.","PeriodicalId":302578,"journal":{"name":"Journal of Nuclear Medicine and Radiation Therapy","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Both Percent Diameter Stenosis (%DS) and Coronary Flow Reserve (CFR) can be Derived Directly from Myocardial Perfusion Imaging (MPI) using FMTVDM © ℗ and Measurement of Isotope Redistribution\",\"authors\":\"R. M. Fleming, M. Fleming, T. Chaudhuri, A. McKusick, W. Dooley, Charles Glover\",\"doi\":\"10.4172/2155-9619.1000353\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Scientifically published studies have demonstrated that all isotopes, including Sestamibi redistribute. Measurement of this redistribution using FMTVDM©℗ provides an accurate method for determining wash-in and washout. Methods: Using FMTVDM©℗ 1040 human coronary arteries were studied to determine their wash-in and washout redistribution measured on a pixel-by-pixel basis. From FMTVDM©℗ the percent diameter stenosis (%DS) for each artery was determined. This %DS was then used to calculate coronary flow reserve (Calculated SFR) using a proprietary quadratic equation (QCFR©, FCFR©) previously derived from quantitative coronary arteriography (QCA) measurements. These calculated CFR values were then compared with the actual measured CFR obtained directly from QCA. Results: The results of the calculated CFR from FMTVDM©℗ with that obtained by direct QCA measurement showed a regression analysis of y= (0.8758•x)+0.4291, where y=the QCFR© and x=the QCA measured CFR. The R2 value (coefficient of determination) for this demonstrated a strong relationship at 0.87582. Conclusions: The use of the FMTVDM©℗ for measurement of isotope redistribution, including Sestamibi, provides an accurate quantitative method for determining both redistribution wash-in and redistribution washout, from which %DS can be calculated on a pixel-by-pixel basis. This %DS can then be used with the proprietary equation (QCFR©, FCFR©) to calculate the CFR directly from the MPI result using FMTVDM©℗. The implementation of this power tool, will provide for additional determination of the physiological effect of CAD without requiring additional QCA equipment and expertise costs, making QCFR© possible in most if not all hospitals with nuclear medicine departments.\",\"PeriodicalId\":302578,\"journal\":{\"name\":\"Journal of Nuclear Medicine and Radiation Therapy\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-02-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Nuclear Medicine and Radiation Therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4172/2155-9619.1000353\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nuclear Medicine and Radiation Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2155-9619.1000353","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13
Both Percent Diameter Stenosis (%DS) and Coronary Flow Reserve (CFR) can be Derived Directly from Myocardial Perfusion Imaging (MPI) using FMTVDM © ℗ and Measurement of Isotope Redistribution
Background: Scientifically published studies have demonstrated that all isotopes, including Sestamibi redistribute. Measurement of this redistribution using FMTVDM©℗ provides an accurate method for determining wash-in and washout. Methods: Using FMTVDM©℗ 1040 human coronary arteries were studied to determine their wash-in and washout redistribution measured on a pixel-by-pixel basis. From FMTVDM©℗ the percent diameter stenosis (%DS) for each artery was determined. This %DS was then used to calculate coronary flow reserve (Calculated SFR) using a proprietary quadratic equation (QCFR©, FCFR©) previously derived from quantitative coronary arteriography (QCA) measurements. These calculated CFR values were then compared with the actual measured CFR obtained directly from QCA. Results: The results of the calculated CFR from FMTVDM©℗ with that obtained by direct QCA measurement showed a regression analysis of y= (0.8758•x)+0.4291, where y=the QCFR© and x=the QCA measured CFR. The R2 value (coefficient of determination) for this demonstrated a strong relationship at 0.87582. Conclusions: The use of the FMTVDM©℗ for measurement of isotope redistribution, including Sestamibi, provides an accurate quantitative method for determining both redistribution wash-in and redistribution washout, from which %DS can be calculated on a pixel-by-pixel basis. This %DS can then be used with the proprietary equation (QCFR©, FCFR©) to calculate the CFR directly from the MPI result using FMTVDM©℗. The implementation of this power tool, will provide for additional determination of the physiological effect of CAD without requiring additional QCA equipment and expertise costs, making QCFR© possible in most if not all hospitals with nuclear medicine departments.