多跨石砌体拱桥承载能力评价的三维有限元建模——以查士丁尼桥为例

V. Mentese, O. Celik
{"title":"多跨石砌体拱桥承载能力评价的三维有限元建模——以查士丁尼桥为例","authors":"V. Mentese, O. Celik","doi":"10.23967/sahc.2021.002","DOIUrl":null,"url":null,"abstract":"Substantial part of the heritage structures in Turkey is historic masonry arch bridges. An important issue has always been to understand the true structural behaviour of such structures. To address this issue and to explore modeling issues, a numerical work has been initiated to better preserve and transfer this heritage to the next eras. However, complexity of such bridges and difficulties in determining their true load carrying capacities are the main handicaps during structural evaluation. A case study is preferred to explain modeling issues. With its historical background, current situation, geometric and material properties, this work presents a numerical investigation into the historic multi-span stone masonry arch Justinian’s (or Sangarius) Bridge located in the city of Sakarya in Turkey over the Sakarya River. The bridge was built in between the years of 553-562 A.D within the 6th Century by order of Emperor Justinian (M.S. 523-567) of the East-Roman Empire. This bridge in which restoration work is underway, is a rare sample of such bridges that has reached to the present day. A three–dimensional finite element model of the bridge was generated in DIANA FEA software using isotropic solid elements. In the developed FE model, the main structural elements, such as stone piers, stone inner and outer arches, spandrel walls, infill, bridge slab, and the parapets were modeled individually. Inelastic structural behavior and collapse mechanism of the , are investigated under vertical incremental static bridge loading for three different load cases (the quarter (1/4), one-third (1/3), and middle (1/2) of the maximum span of the bridge). results obtained for lower and upper values Nonlinear static analysis of the tensile fracture energy of the stone material, are compared. The loading procedure was carried out as vertical static loading with increments of 200 kN throughout the full width of bridge between the parapets. Numerical results showed that the value of fracture energy in tension significantly affect the load carrying capacity and failure mechanism of multi-span masonry arch bridges. A more realistic nonlinear response has been obtained for an upper value of the tensile fracture energy of the stone material. The bridge model collapses by a-three-hinge mechanism occuring at the loaded arch in the upper value of the tensile fracture energy. The most critical loading point of the bridge is determined as the quarter-span. Loading position of masonry arch bridges considerably affects collapse mechanisms and corresponding load carrying capacities of such systems. *Corresponding author: Formerly, M.Sc., Department of Architecture, Istanbul Technical University (ITU) Tel.: +90 554 657 8773.","PeriodicalId":176260,"journal":{"name":"12th International Conference on Structural Analysis of Historical Constructions","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"3D FE Modeling of Multi-Span Stone Masonry Arch Bridges for the Assessment of Load Carrying Capacity: the Case of Justinian’s Bridge\",\"authors\":\"V. Mentese, O. Celik\",\"doi\":\"10.23967/sahc.2021.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Substantial part of the heritage structures in Turkey is historic masonry arch bridges. An important issue has always been to understand the true structural behaviour of such structures. To address this issue and to explore modeling issues, a numerical work has been initiated to better preserve and transfer this heritage to the next eras. However, complexity of such bridges and difficulties in determining their true load carrying capacities are the main handicaps during structural evaluation. A case study is preferred to explain modeling issues. With its historical background, current situation, geometric and material properties, this work presents a numerical investigation into the historic multi-span stone masonry arch Justinian’s (or Sangarius) Bridge located in the city of Sakarya in Turkey over the Sakarya River. The bridge was built in between the years of 553-562 A.D within the 6th Century by order of Emperor Justinian (M.S. 523-567) of the East-Roman Empire. This bridge in which restoration work is underway, is a rare sample of such bridges that has reached to the present day. A three–dimensional finite element model of the bridge was generated in DIANA FEA software using isotropic solid elements. In the developed FE model, the main structural elements, such as stone piers, stone inner and outer arches, spandrel walls, infill, bridge slab, and the parapets were modeled individually. Inelastic structural behavior and collapse mechanism of the , are investigated under vertical incremental static bridge loading for three different load cases (the quarter (1/4), one-third (1/3), and middle (1/2) of the maximum span of the bridge). results obtained for lower and upper values Nonlinear static analysis of the tensile fracture energy of the stone material, are compared. The loading procedure was carried out as vertical static loading with increments of 200 kN throughout the full width of bridge between the parapets. Numerical results showed that the value of fracture energy in tension significantly affect the load carrying capacity and failure mechanism of multi-span masonry arch bridges. A more realistic nonlinear response has been obtained for an upper value of the tensile fracture energy of the stone material. The bridge model collapses by a-three-hinge mechanism occuring at the loaded arch in the upper value of the tensile fracture energy. The most critical loading point of the bridge is determined as the quarter-span. Loading position of masonry arch bridges considerably affects collapse mechanisms and corresponding load carrying capacities of such systems. *Corresponding author: Formerly, M.Sc., Department of Architecture, Istanbul Technical University (ITU) Tel.: +90 554 657 8773.\",\"PeriodicalId\":176260,\"journal\":{\"name\":\"12th International Conference on Structural Analysis of Historical Constructions\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"12th International Conference on Structural Analysis of Historical Constructions\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23967/sahc.2021.002\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"12th International Conference on Structural Analysis of Historical Constructions","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23967/sahc.2021.002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

土耳其遗产建筑的很大一部分是历史悠久的砖石拱桥。一个重要的问题一直是了解这种结构的真实结构行为。为了解决这个问题并探索建模问题,一项数值工作已经开始,以更好地保存和转移这一遗产到下一个时代。然而,此类桥梁的复杂性和难以确定其真实承载能力是结构评估的主要障碍。最好使用案例研究来解释建模问题。根据其历史背景、现状、几何和材料特性,本作品对位于土耳其萨卡里亚市萨卡里亚河上的历史多跨石砌拱桥查士丁尼(或桑贾瑞斯)桥进行了数值研究。这座桥建于公元553-562年间。公元6世纪由东罗马帝国的查士丁尼皇帝(ms . 523-567)下令修建。这座桥正在进行修复工作,是迄今为止这种桥梁的罕见样本。采用各向同性实体单元,在DIANA有限元软件中建立了桥梁的三维有限元模型。在建立的有限元模型中,分别对石墩、石质内外拱、拱肩墙、填充物、桥板和护墙等主要结构单元进行了建模。针对三种不同的荷载情况(桥梁最大跨度的四分之一(1/4)、三分之一(1/3)和中间(1/2),研究了垂直增量静力加载下桥梁的非弹性结构性能和破坏机理。本文对岩石材料拉伸断裂能的非线性静力分析结果进行了比较。加载过程以垂直静态加载方式进行,在整个胸墙之间的桥梁全宽度上增加200 kN。数值计算结果表明,受拉断裂能的大小对多跨砌体拱桥的承载能力和破坏机理有显著影响。对于岩石材料的拉伸断裂能上限,得到了更为真实的非线性响应。桥梁模型在受拉断裂能上限处,以三铰机制在荷载拱处发生垮塌。确定桥梁的最关键荷载点为四分之一跨。砌体拱桥的荷载位置对其倒塌机理和承载能力影响很大。*通讯作者:原伊斯坦布尔技术大学(ITU)建筑系M.Sc. Tel: +90 554 657 8773。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
3D FE Modeling of Multi-Span Stone Masonry Arch Bridges for the Assessment of Load Carrying Capacity: the Case of Justinian’s Bridge
Substantial part of the heritage structures in Turkey is historic masonry arch bridges. An important issue has always been to understand the true structural behaviour of such structures. To address this issue and to explore modeling issues, a numerical work has been initiated to better preserve and transfer this heritage to the next eras. However, complexity of such bridges and difficulties in determining their true load carrying capacities are the main handicaps during structural evaluation. A case study is preferred to explain modeling issues. With its historical background, current situation, geometric and material properties, this work presents a numerical investigation into the historic multi-span stone masonry arch Justinian’s (or Sangarius) Bridge located in the city of Sakarya in Turkey over the Sakarya River. The bridge was built in between the years of 553-562 A.D within the 6th Century by order of Emperor Justinian (M.S. 523-567) of the East-Roman Empire. This bridge in which restoration work is underway, is a rare sample of such bridges that has reached to the present day. A three–dimensional finite element model of the bridge was generated in DIANA FEA software using isotropic solid elements. In the developed FE model, the main structural elements, such as stone piers, stone inner and outer arches, spandrel walls, infill, bridge slab, and the parapets were modeled individually. Inelastic structural behavior and collapse mechanism of the , are investigated under vertical incremental static bridge loading for three different load cases (the quarter (1/4), one-third (1/3), and middle (1/2) of the maximum span of the bridge). results obtained for lower and upper values Nonlinear static analysis of the tensile fracture energy of the stone material, are compared. The loading procedure was carried out as vertical static loading with increments of 200 kN throughout the full width of bridge between the parapets. Numerical results showed that the value of fracture energy in tension significantly affect the load carrying capacity and failure mechanism of multi-span masonry arch bridges. A more realistic nonlinear response has been obtained for an upper value of the tensile fracture energy of the stone material. The bridge model collapses by a-three-hinge mechanism occuring at the loaded arch in the upper value of the tensile fracture energy. The most critical loading point of the bridge is determined as the quarter-span. Loading position of masonry arch bridges considerably affects collapse mechanisms and corresponding load carrying capacities of such systems. *Corresponding author: Formerly, M.Sc., Department of Architecture, Istanbul Technical University (ITU) Tel.: +90 554 657 8773.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信