Mengmeng Cheng, Shuwen Guo, Bo Fan, Quan Wan, Zuxiang Wen, Dacheng Xu
{"title":"蛛网状陀螺仪再平衡力控制的自动模式匹配和比例因子可调检测系统","authors":"Mengmeng Cheng, Shuwen Guo, Bo Fan, Quan Wan, Zuxiang Wen, Dacheng Xu","doi":"10.1109/ICSENS.2018.8589903","DOIUrl":null,"url":null,"abstract":"An automatic mode-matching circuit and scale factor adjustable detection system for force to rebalance cobweb-like disk resonator gyroscopes (DRG) are presented in this work. The mode-matching circuit uses a phase detection system to track and control phase difference between output signal of drive mode and quadrature error to match the mode resonance frequencies, which results in a significant performance improvement. Besides, a new scale factor adjustment method is proposed, which could be used in force to rebalance detection system of cobweb-like DRG. The experimental results show that the scale factor of gyroscope with closed loop controlled sense mode improves from 7.9mV/°/s to 19.1mV/°/s, and the bias instability improves from 11.19°/hr to O.43°/hr.","PeriodicalId":405874,"journal":{"name":"2018 IEEE SENSORS","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Automatic Mode-Matching and Scale Factor Adjustable Detection System for Force to Rebalance Control of Cobweb-Like Gyroscopes\",\"authors\":\"Mengmeng Cheng, Shuwen Guo, Bo Fan, Quan Wan, Zuxiang Wen, Dacheng Xu\",\"doi\":\"10.1109/ICSENS.2018.8589903\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An automatic mode-matching circuit and scale factor adjustable detection system for force to rebalance cobweb-like disk resonator gyroscopes (DRG) are presented in this work. The mode-matching circuit uses a phase detection system to track and control phase difference between output signal of drive mode and quadrature error to match the mode resonance frequencies, which results in a significant performance improvement. Besides, a new scale factor adjustment method is proposed, which could be used in force to rebalance detection system of cobweb-like DRG. The experimental results show that the scale factor of gyroscope with closed loop controlled sense mode improves from 7.9mV/°/s to 19.1mV/°/s, and the bias instability improves from 11.19°/hr to O.43°/hr.\",\"PeriodicalId\":405874,\"journal\":{\"name\":\"2018 IEEE SENSORS\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE SENSORS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2018.8589903\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE SENSORS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2018.8589903","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文提出了一种用于蛛网状圆盘谐振陀螺仪(DRG)再平衡力的自动模式匹配电路和比例因子可调检测系统。模式匹配电路采用鉴相系统跟踪和控制驱动模式输出信号与正交误差之间的相位差,以匹配模式谐振频率,从而显著提高了性能。此外,提出了一种新的尺度因子调整方法,可有效地用于网状DRG检测系统的再平衡。实验结果表明,采用闭环控制传感模式的陀螺仪的比例因子从7.9mV/°/s提高到19.1mV/°/s,偏置不稳定性从11.19°/hr提高到0.43°/hr。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Automatic Mode-Matching and Scale Factor Adjustable Detection System for Force to Rebalance Control of Cobweb-Like Gyroscopes
An automatic mode-matching circuit and scale factor adjustable detection system for force to rebalance cobweb-like disk resonator gyroscopes (DRG) are presented in this work. The mode-matching circuit uses a phase detection system to track and control phase difference between output signal of drive mode and quadrature error to match the mode resonance frequencies, which results in a significant performance improvement. Besides, a new scale factor adjustment method is proposed, which could be used in force to rebalance detection system of cobweb-like DRG. The experimental results show that the scale factor of gyroscope with closed loop controlled sense mode improves from 7.9mV/°/s to 19.1mV/°/s, and the bias instability improves from 11.19°/hr to O.43°/hr.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信