{"title":"鲁棒自适应预测负荷频率控制器补偿模型失配","authors":"S. F. Siraj, M. Muin, K. M. Nor, S. Rahim, M. Mohamad, E. C. Mid","doi":"10.1109/PEOCO.2010.5559181","DOIUrl":null,"url":null,"abstract":"The paper describes the design and implementation of a self-tuning load frequency controller (LFC) of a power system based on the adaptive generalized predictive (AGP) controller. The application of predictive control in power system control is considered due to its ability to handle disturbances and un modeled dynamics often encountered in interconnected power system environments. The system dynamics is modeled and linearized around its operating point to represent plant in the controller auto-regressive integrated moving average (CARIMA) form suitable for prediction with the presence of disturbance. Simulation results show that the controller exhibits robustness in handling both problems with proper tuning of its parameters, especially when compared to the normal adaptive control methods of minimum variance and pole assignment.","PeriodicalId":379868,"journal":{"name":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A robust adaptive predictive load frequency controller to compensate for model mismatch\",\"authors\":\"S. F. Siraj, M. Muin, K. M. Nor, S. Rahim, M. Mohamad, E. C. Mid\",\"doi\":\"10.1109/PEOCO.2010.5559181\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper describes the design and implementation of a self-tuning load frequency controller (LFC) of a power system based on the adaptive generalized predictive (AGP) controller. The application of predictive control in power system control is considered due to its ability to handle disturbances and un modeled dynamics often encountered in interconnected power system environments. The system dynamics is modeled and linearized around its operating point to represent plant in the controller auto-regressive integrated moving average (CARIMA) form suitable for prediction with the presence of disturbance. Simulation results show that the controller exhibits robustness in handling both problems with proper tuning of its parameters, especially when compared to the normal adaptive control methods of minimum variance and pole assignment.\",\"PeriodicalId\":379868,\"journal\":{\"name\":\"2010 4th International Power Engineering and Optimization Conference (PEOCO)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 4th International Power Engineering and Optimization Conference (PEOCO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEOCO.2010.5559181\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEOCO.2010.5559181","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

介绍了一种基于自适应广义预测(AGP)控制器的电力系统负荷频率自整定控制器(LFC)的设计与实现。预测控制在电力系统控制中的应用被认为是由于它能够处理在互联电力系统环境中经常遇到的干扰和未建模的动态。对系统动力学进行建模,并围绕其工作点进行线性化,以适合于存在扰动时预测的控制器自回归积分移动平均(CARIMA)形式表示对象。仿真结果表明,与常规的最小方差和极点配置自适应控制方法相比,该控制器在适当调整参数的情况下具有较好的鲁棒性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A robust adaptive predictive load frequency controller to compensate for model mismatch
The paper describes the design and implementation of a self-tuning load frequency controller (LFC) of a power system based on the adaptive generalized predictive (AGP) controller. The application of predictive control in power system control is considered due to its ability to handle disturbances and un modeled dynamics often encountered in interconnected power system environments. The system dynamics is modeled and linearized around its operating point to represent plant in the controller auto-regressive integrated moving average (CARIMA) form suitable for prediction with the presence of disturbance. Simulation results show that the controller exhibits robustness in handling both problems with proper tuning of its parameters, especially when compared to the normal adaptive control methods of minimum variance and pole assignment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信