P. Martins, V. B. Melo, Gilielson F. da Paz, F. V. Rocha, L. F. M. de Lucena
{"title":"单相开路故障下感应电机驱动系统的预测转矩控制","authors":"P. Martins, V. B. Melo, Gilielson F. da Paz, F. V. Rocha, L. F. M. de Lucena","doi":"10.1109/COBEP53665.2021.9684061","DOIUrl":null,"url":null,"abstract":"This paper discusses the Predictive Torque Control (PTC) applied to three three-phase fault-tolerant induction machine drive systems operating under a single-phase open-circuit fault. Performed simulations and experiments prove that PTC-based fault compensation strategies provides proper fault-tolerant operation. Furthermore, a performance comparison between Field Oriented Control (FOC) and PTC is carried out, which shows that PTC provides a smoother and faster transient response when the system migrates from healthy to post-fault operation, while FOC provides steady-state lower current ripple.","PeriodicalId":442384,"journal":{"name":"2021 Brazilian Power Electronics Conference (COBEP)","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Predictive Torque Control Applied to Induction Machine Drive Systems Operating Under Single-Phase Open-Circuit Fault\",\"authors\":\"P. Martins, V. B. Melo, Gilielson F. da Paz, F. V. Rocha, L. F. M. de Lucena\",\"doi\":\"10.1109/COBEP53665.2021.9684061\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses the Predictive Torque Control (PTC) applied to three three-phase fault-tolerant induction machine drive systems operating under a single-phase open-circuit fault. Performed simulations and experiments prove that PTC-based fault compensation strategies provides proper fault-tolerant operation. Furthermore, a performance comparison between Field Oriented Control (FOC) and PTC is carried out, which shows that PTC provides a smoother and faster transient response when the system migrates from healthy to post-fault operation, while FOC provides steady-state lower current ripple.\",\"PeriodicalId\":442384,\"journal\":{\"name\":\"2021 Brazilian Power Electronics Conference (COBEP)\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 Brazilian Power Electronics Conference (COBEP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/COBEP53665.2021.9684061\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Brazilian Power Electronics Conference (COBEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COBEP53665.2021.9684061","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Predictive Torque Control Applied to Induction Machine Drive Systems Operating Under Single-Phase Open-Circuit Fault
This paper discusses the Predictive Torque Control (PTC) applied to three three-phase fault-tolerant induction machine drive systems operating under a single-phase open-circuit fault. Performed simulations and experiments prove that PTC-based fault compensation strategies provides proper fault-tolerant operation. Furthermore, a performance comparison between Field Oriented Control (FOC) and PTC is carried out, which shows that PTC provides a smoother and faster transient response when the system migrates from healthy to post-fault operation, while FOC provides steady-state lower current ripple.