A. Jalilian, Milad Mohamadyari, Homayun Rahimi, M. Karami
{"title":"考虑保控装置故障后最优运行的配电网可靠性评估","authors":"A. Jalilian, Milad Mohamadyari, Homayun Rahimi, M. Karami","doi":"10.52547/ijrtei.1.1.1","DOIUrl":null,"url":null,"abstract":"Article history: Received 23 November 2021 Received in revised form 05 February 2022 Accepted 24 February 2022 The reliability level of the distribution network is a judgment tool of the grid and protection design quality, the effectiveness of the fault management unit, and customers’ satisfaction. In this paper, a new approach is presented to evaluate common reliability indices namely ENS, SAIDI, SAIFI, MAIFIe, etc., while reliability improvement via optimal post-fault restoration describes the coordinated operation of various protection and control devices in temporary and permanent fault event conditions. Customers’ outage times are calculated considering different switching operation times to capture manual operation issues, e.g., traffic level, geographical issues, fuse replacements, etc. The optimal service restoration scheme being formulated in a mixed-integer linear programming (MILP) fashion is constrained to network technical limitations, e.g., line thermal capacity, load points voltage level, DG units’ parameters, and island operation. The performance of the proposed framework is verified in IEEE 33-bus test system.","PeriodicalId":430029,"journal":{"name":"Research and Technology in the Electrical Industry","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Power Distribution Grid Reliability Assessment Considering Protection and Control Devices’ Optimal Post-Fault Operation\",\"authors\":\"A. Jalilian, Milad Mohamadyari, Homayun Rahimi, M. Karami\",\"doi\":\"10.52547/ijrtei.1.1.1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Article history: Received 23 November 2021 Received in revised form 05 February 2022 Accepted 24 February 2022 The reliability level of the distribution network is a judgment tool of the grid and protection design quality, the effectiveness of the fault management unit, and customers’ satisfaction. In this paper, a new approach is presented to evaluate common reliability indices namely ENS, SAIDI, SAIFI, MAIFIe, etc., while reliability improvement via optimal post-fault restoration describes the coordinated operation of various protection and control devices in temporary and permanent fault event conditions. Customers’ outage times are calculated considering different switching operation times to capture manual operation issues, e.g., traffic level, geographical issues, fuse replacements, etc. The optimal service restoration scheme being formulated in a mixed-integer linear programming (MILP) fashion is constrained to network technical limitations, e.g., line thermal capacity, load points voltage level, DG units’ parameters, and island operation. The performance of the proposed framework is verified in IEEE 33-bus test system.\",\"PeriodicalId\":430029,\"journal\":{\"name\":\"Research and Technology in the Electrical Industry\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Research and Technology in the Electrical Industry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52547/ijrtei.1.1.1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research and Technology in the Electrical Industry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52547/ijrtei.1.1.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Power Distribution Grid Reliability Assessment Considering Protection and Control Devices’ Optimal Post-Fault Operation
Article history: Received 23 November 2021 Received in revised form 05 February 2022 Accepted 24 February 2022 The reliability level of the distribution network is a judgment tool of the grid and protection design quality, the effectiveness of the fault management unit, and customers’ satisfaction. In this paper, a new approach is presented to evaluate common reliability indices namely ENS, SAIDI, SAIFI, MAIFIe, etc., while reliability improvement via optimal post-fault restoration describes the coordinated operation of various protection and control devices in temporary and permanent fault event conditions. Customers’ outage times are calculated considering different switching operation times to capture manual operation issues, e.g., traffic level, geographical issues, fuse replacements, etc. The optimal service restoration scheme being formulated in a mixed-integer linear programming (MILP) fashion is constrained to network technical limitations, e.g., line thermal capacity, load points voltage level, DG units’ parameters, and island operation. The performance of the proposed framework is verified in IEEE 33-bus test system.