{"title":"牙科合金和过敏。病例报告)。","authors":"L Figgener","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The case of a 67-year-old woman, who had been wearing an upper partial removable denture with a cast metal framework made of CoCrMo alloy for years without any problems, is described. After the extraction of a molar tooth a nickel alloy retention was soldered to the framework. Following reinsertion allergic reactions appeared. The soldered joint showed considerable corrosion. After removing the retention and the soldered joint, the allergic reactions disappeared, although an epicutanceous test had revealed a positive reaction to cobalt. This case supports the high corrosion resistance and biocompatibility reported for CoCrMo alloys in the literature and the loss of these properties due to inadequate processing. Furthermore, the case illustrates a true allergic reaction. In contrast to the rather indiscriminate use of the term allergy to describe various vague disorders, this diagnosis should be restricted to clearly identified clinical situations.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":"47 1","pages":"33-5"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Dental alloys and allergy. Case report].\",\"authors\":\"L Figgener\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The case of a 67-year-old woman, who had been wearing an upper partial removable denture with a cast metal framework made of CoCrMo alloy for years without any problems, is described. After the extraction of a molar tooth a nickel alloy retention was soldered to the framework. Following reinsertion allergic reactions appeared. The soldered joint showed considerable corrosion. After removing the retention and the soldered joint, the allergic reactions disappeared, although an epicutanceous test had revealed a positive reaction to cobalt. This case supports the high corrosion resistance and biocompatibility reported for CoCrMo alloys in the literature and the loss of these properties due to inadequate processing. Furthermore, the case illustrates a true allergic reaction. In contrast to the rather indiscriminate use of the term allergy to describe various vague disorders, this diagnosis should be restricted to clearly identified clinical situations.</p>\",\"PeriodicalId\":11244,\"journal\":{\"name\":\"Deutsche zahnarztliche Zeitschrift\",\"volume\":\"47 1\",\"pages\":\"33-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Deutsche zahnarztliche Zeitschrift\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Deutsche zahnarztliche Zeitschrift","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文描述了一名67岁的妇女,她多年来一直佩戴CoCrMo合金铸造金属框架的上半部分可摘义齿,没有任何问题。拔除臼齿后,将镍合金固位焊到框架上。重新插入后出现过敏反应。焊接的接头显示出相当大的腐蚀。在去除保留物和焊接接头后,过敏反应消失,尽管表皮测试显示对钴有阳性反应。这一案例支持了文献中报道的CoCrMo合金的高耐腐蚀性和生物相容性,以及由于加工不当而导致这些性能的丧失。此外,该病例说明了真正的过敏反应。与不加区分地使用“过敏”一词来描述各种模糊的疾病相反,这种诊断应限于明确确定的临床情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Dental alloys and allergy. Case report].

The case of a 67-year-old woman, who had been wearing an upper partial removable denture with a cast metal framework made of CoCrMo alloy for years without any problems, is described. After the extraction of a molar tooth a nickel alloy retention was soldered to the framework. Following reinsertion allergic reactions appeared. The soldered joint showed considerable corrosion. After removing the retention and the soldered joint, the allergic reactions disappeared, although an epicutanceous test had revealed a positive reaction to cobalt. This case supports the high corrosion resistance and biocompatibility reported for CoCrMo alloys in the literature and the loss of these properties due to inadequate processing. Furthermore, the case illustrates a true allergic reaction. In contrast to the rather indiscriminate use of the term allergy to describe various vague disorders, this diagnosis should be restricted to clearly identified clinical situations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信