{"title":"设计单相五级封装U-Cell逆变器的独立和电网连接模式","authors":"M. Faizan, A. Tariq","doi":"10.1109/SeFeT55524.2022.9908917","DOIUrl":null,"url":null,"abstract":"The Packed U-Cell (PUC) inverter now has a new mode of operation is presented in this work. The PUC five levels inverter is a switching inverter that is integrated into the process, is designed using a sensor-free voltage control system that uses redundant switching states. The Voltage control without sensors maintains half the voltage of the DC source on the DC capacitor, resulting in a minimal harmonic distortion symmetric five-level voltage waveform at the output. The suggested converter’s voltage regulator with no sensors simplifies the control system’s complexity, making it suitable for industrial applications. The introduced sensor-less technology is being used in a grid-connected application PUC5In order to inject real and reactive power into the grid with a changeable power factor from the inverter, an external current controller was employed, The PUC auxiliary DC bus, on the other hand, is controlled solely by a sensor free controller and a new switching scheme. The proposed PUC5 inverter’s simulation results in grid-connected and stand-alone operation modes demonstrate the sensor free voltage control’s a quick response time and good dynamic performance in achieving the necessary DC capacitor voltage balance.","PeriodicalId":262863,"journal":{"name":"2022 IEEE 2nd International Conference on Sustainable Energy and Future Electric Transportation (SeFeT)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design Single Phase Five Level Packed U-Cell Inverter For Standalone and Grid Connected Modes\",\"authors\":\"M. Faizan, A. Tariq\",\"doi\":\"10.1109/SeFeT55524.2022.9908917\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Packed U-Cell (PUC) inverter now has a new mode of operation is presented in this work. The PUC five levels inverter is a switching inverter that is integrated into the process, is designed using a sensor-free voltage control system that uses redundant switching states. The Voltage control without sensors maintains half the voltage of the DC source on the DC capacitor, resulting in a minimal harmonic distortion symmetric five-level voltage waveform at the output. The suggested converter’s voltage regulator with no sensors simplifies the control system’s complexity, making it suitable for industrial applications. The introduced sensor-less technology is being used in a grid-connected application PUC5In order to inject real and reactive power into the grid with a changeable power factor from the inverter, an external current controller was employed, The PUC auxiliary DC bus, on the other hand, is controlled solely by a sensor free controller and a new switching scheme. The proposed PUC5 inverter’s simulation results in grid-connected and stand-alone operation modes demonstrate the sensor free voltage control’s a quick response time and good dynamic performance in achieving the necessary DC capacitor voltage balance.\",\"PeriodicalId\":262863,\"journal\":{\"name\":\"2022 IEEE 2nd International Conference on Sustainable Energy and Future Electric Transportation (SeFeT)\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE 2nd International Conference on Sustainable Energy and Future Electric Transportation (SeFeT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SeFeT55524.2022.9908917\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 2nd International Conference on Sustainable Energy and Future Electric Transportation (SeFeT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SeFeT55524.2022.9908917","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design Single Phase Five Level Packed U-Cell Inverter For Standalone and Grid Connected Modes
The Packed U-Cell (PUC) inverter now has a new mode of operation is presented in this work. The PUC five levels inverter is a switching inverter that is integrated into the process, is designed using a sensor-free voltage control system that uses redundant switching states. The Voltage control without sensors maintains half the voltage of the DC source on the DC capacitor, resulting in a minimal harmonic distortion symmetric five-level voltage waveform at the output. The suggested converter’s voltage regulator with no sensors simplifies the control system’s complexity, making it suitable for industrial applications. The introduced sensor-less technology is being used in a grid-connected application PUC5In order to inject real and reactive power into the grid with a changeable power factor from the inverter, an external current controller was employed, The PUC auxiliary DC bus, on the other hand, is controlled solely by a sensor free controller and a new switching scheme. The proposed PUC5 inverter’s simulation results in grid-connected and stand-alone operation modes demonstrate the sensor free voltage control’s a quick response time and good dynamic performance in achieving the necessary DC capacitor voltage balance.