{"title":"电絮凝去除水中As(V)离子条件的优化","authors":"A. Altangerel, Damdin Nomin-Erdene, D. Sarangerel","doi":"10.5564/bicct.v4i9.1811","DOIUrl":null,"url":null,"abstract":" In recent years, the arsenic content of groundwater and soil due to the mining processes and natural and/or anthropogenic sources exceeds the permissible level, leading to adverse effects on human health and the ecosystem. The paper provides the optimized condition for the arsenic removal from the aqueous media using electrocoagulation, which is no additional reagents/chemicals, in situ generation of coagulants continuously, low energy consumption. The optimal conditions were found to be as follows: pH 7, electrolyte concentration NaCl 0.5 g L-1, current density 20 mA cm-2, and operational time 20 minutes, initial concentration of arsenic 50 mg L-1. Under the optimal condition, the maximum removal efficiency was 99.6%. Generally, the experimental results showed that the removal efficiency of As(V) from the aqueous medium was higher than 95% at pH = 4-8 ranges, 90% at the electrolyte concentration in the range of 0.25 g L-1 to 0.75 g L-1 , and 96% at the current density in the range of 15 mA cm-2 - 60 mA cm-2 respectively. Considering the variation of oxidation-reduction potential and pH during the electrocoagulation and FTIR spectra of solid residue, we found that As(V) was removed through the chemical precipitation (FeAsO4) and adsorption (Fe(OH)3×HAsO42-).\n \nУсан орчноос As(V) ионы агуулгыг бууруулах электрокоагуляцийн зохистой нөхцөлийг тогтоох судалгаа\nХураангуй: Сүүлийн жилүүдэд эрдэс түүхий эдийн олборлолт, арсен агуулсан эрдэс чулуулгийн өгөршилөөр гадаргын болон гүний усан дахь арсены (As) агуулга хүлцэх агууламжаас ихсэх тохиолдлууд гарч байна. Энэ судалгааны ажлаар коагулянтаа орчинд нь тасралтгүй үүсгэдэг, нэмэлт урвалж шаарддаггүй, цахилгааны зарцуулалт багатай электрокоагуляцийн аргаар усан уусмал дахь As(V)-ыг тунадасжуулах зохистой нөхцөлийг тогтоох ажлыг хийж, үр дүнг спектрофотометр, индукцийн холбоост плазм-масс спектрометр, потенциометрийн аргаар тодорхойллоо. Зохистой нөхцөлийг тодорхойлох туршилтын дүнгээс харахад, усан орчноос As(V)-ын тунадасжуулалт рН=4-8-ын утганд >95%, электролитын концентрацийн 0.25 – 0.75 г/л мужид >90%, гүйдлийн нягтын 15 – 60 мА/см2 мужид >96% бүтээмжтэй байв. Уусмалын рН ~7, NaCl-ын концентраци 0.5 г/л, гүйдлийн нягт 20 мА/см2 үед 50 мг/л концентрацитай As(V)-ын зайлуулалт хамгийн их буюу 99.6% нь усан орчноос тунадасжиж байлаа. Исэлдэх ангижрах потенциал, рН-ын хугацаанаас хамаарах хамаарал, үүссэн тунадсын нил улаан туяаны спектрийн шинжилгээний үр дүнгээр, электрокоагуляциар As(V)-ын зайлуулалт нь химийн тунадасжилт (FeAsO4), адсорбц (Fe(OH)3×HAsO42-)-ийн процессоор явагддагийг тогтоолоо.\nТүлхүүр үг: төмөр электрод, коагулянт, адсорбц, арсенат ион","PeriodicalId":118037,"journal":{"name":"Bulletin of the Institute of Chemistry and Chemical Technology","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimization of electrocoagulation condition for the removal of As(V) ions from aqueous media\",\"authors\":\"A. Altangerel, Damdin Nomin-Erdene, D. Sarangerel\",\"doi\":\"10.5564/bicct.v4i9.1811\",\"DOIUrl\":null,\"url\":null,\"abstract\":\" In recent years, the arsenic content of groundwater and soil due to the mining processes and natural and/or anthropogenic sources exceeds the permissible level, leading to adverse effects on human health and the ecosystem. The paper provides the optimized condition for the arsenic removal from the aqueous media using electrocoagulation, which is no additional reagents/chemicals, in situ generation of coagulants continuously, low energy consumption. The optimal conditions were found to be as follows: pH 7, electrolyte concentration NaCl 0.5 g L-1, current density 20 mA cm-2, and operational time 20 minutes, initial concentration of arsenic 50 mg L-1. Under the optimal condition, the maximum removal efficiency was 99.6%. Generally, the experimental results showed that the removal efficiency of As(V) from the aqueous medium was higher than 95% at pH = 4-8 ranges, 90% at the electrolyte concentration in the range of 0.25 g L-1 to 0.75 g L-1 , and 96% at the current density in the range of 15 mA cm-2 - 60 mA cm-2 respectively. Considering the variation of oxidation-reduction potential and pH during the electrocoagulation and FTIR spectra of solid residue, we found that As(V) was removed through the chemical precipitation (FeAsO4) and adsorption (Fe(OH)3×HAsO42-).\\n \\nУсан орчноос As(V) ионы агуулгыг бууруулах электрокоагуляцийн зохистой нөхцөлийг тогтоох судалгаа\\nХураангуй: Сүүлийн жилүүдэд эрдэс түүхий эдийн олборлолт, арсен агуулсан эрдэс чулуулгийн өгөршилөөр гадаргын болон гүний усан дахь арсены (As) агуулга хүлцэх агууламжаас ихсэх тохиолдлууд гарч байна. Энэ судалгааны ажлаар коагулянтаа орчинд нь тасралтгүй үүсгэдэг, нэмэлт урвалж шаарддаггүй, цахилгааны зарцуулалт багатай электрокоагуляцийн аргаар усан уусмал дахь As(V)-ыг тунадасжуулах зохистой нөхцөлийг тогтоох ажлыг хийж, үр дүнг спектрофотометр, индукцийн холбоост плазм-масс спектрометр, потенциометрийн аргаар тодорхойллоо. Зохистой нөхцөлийг тодорхойлох туршилтын дүнгээс харахад, усан орчноос As(V)-ын тунадасжуулалт рН=4-8-ын утганд >95%, электролитын концентрацийн 0.25 – 0.75 г/л мужид >90%, гүйдлийн нягтын 15 – 60 мА/см2 мужид >96% бүтээмжтэй байв. Уусмалын рН ~7, NaCl-ын концентраци 0.5 г/л, гүйдлийн нягт 20 мА/см2 үед 50 мг/л концентрацитай As(V)-ын зайлуулалт хамгийн их буюу 99.6% нь усан орчноос тунадасжиж байлаа. Исэлдэх ангижрах потенциал, рН-ын хугацаанаас хамаарах хамаарал, үүссэн тунадсын нил улаан туяаны спектрийн шинжилгээний үр дүнгээр, электрокоагуляциар As(V)-ын зайлуулалт нь химийн тунадасжилт (FeAsO4), адсорбц (Fe(OH)3×HAsO42-)-ийн процессоор явагддагийг тогтоолоо.\\nТүлхүүр үг: төмөр электрод, коагулянт, адсорбц, арсенат ион\",\"PeriodicalId\":118037,\"journal\":{\"name\":\"Bulletin of the Institute of Chemistry and Chemical Technology\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin of the Institute of Chemistry and Chemical Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5564/bicct.v4i9.1811\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of the Institute of Chemistry and Chemical Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5564/bicct.v4i9.1811","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
近年来,由于采矿过程以及自然和/或人为来源,地下水和土壤中的砷含量超过了允许水平,导致对人类健康和生态系统产生不利影响。本文提出了电絮凝法去除水中砷的最佳条件,即不需要额外的试剂/化学品,连续原位生成絮凝剂,能耗低。最佳工艺条件为:pH 7,电解液浓度NaCl 0.5 g L-1,电流密度20 mA cm-2,操作时间20 min,初始砷浓度50 mg L-1。在最佳条件下,最高去除率为99.6%。实验结果表明,在pH = 4 ~ 8范围内,As(V)的去除率高于95%,在0.25 ~ 0.75 g L-1电解质浓度范围内,As(V)的去除率为90%,在15 mA cm-2 ~ 60 mA cm-2电流密度范围内,As(V)的去除率分别为96%。结合电凝过程中氧化还原电位和pH值的变化以及固体残渣的FTIR光谱,我们发现As(V)是通过化学沉淀(FeAsO4)和吸附(Fe(OH)3×HAsO42-)去除的。Усанорчноос作为(V)ионыагуулгыгбууруулахэлектрокоагуляцийнзохистойнөхцөлийгтогтоохсудалгааХураангуй:Сүүлийнжилүүдэдэрдэстүүхийэдийнолборлол,тарсенагуулсанэрдэсчулуулгийнөгөршилөөргадаргынболонгүнийусандахьарсены(As)агуулгахүлцэхагууламжаасихсэхтохиолдлуудгарчбайна。Энэсудалгааныажлааркоагулянтааорчиндньтасралтгүйүүсгэдэг,нэмэлтурвалжшаарддаггүй,цахилгаанызарцуулалтбагатайэлектрокоагуляцийнаргаарусануусмалдахь(V) -ыгтунадасжуулахзохистойнөхцөлийгтогтоохажлыгхийж,үрдүнгспектрофотометр,индукцийнхолбоостплаз,ммассспектрометр,потенциометрийнаргаартодорхойллоо。Зохистойнөхцөлийгтодорхойлохтуршилтындүнгээсхарахад,усанорчноос(V) -ынтунадасжуулалтрН= 4 - 8 -ынутганд> 95%,электролитынконцентрацийн0.25 - 0.75г/лмужид> 90%,гүйдлийннягтын15 - 60мА/с2ммужид> 96%бүтээмжтэйбайв。УусмалынрН~ 7,氯化钠-ынконцентрац0.5г/лигүйдлийннягт20мА/с2үмем50дг/лконцентрацитай(V) -ынзайлуулалтхамгийнихбую99.6%уньусанорчноостунадасжижбайлаа。Исэлдэхангижрахпотенциал,рН——ынхугацаанаасхамаараххамаарал,үүссэнтунадсыннилулаантуяаныспектрийншинжилгээнийүрдүнгээр,электрокоагуляциар(V) -ынзайлуулалтньхимийнтунадасжилт(FeAsO4),адсорбц(Fe (OH) 3×HAsO42)——ийнпроцессоорявагддагийгтогтоолоо。Түлхүүрүг:төмөрэлектрод,коагулян,тадсорб,царсенатион
Optimization of electrocoagulation condition for the removal of As(V) ions from aqueous media
In recent years, the arsenic content of groundwater and soil due to the mining processes and natural and/or anthropogenic sources exceeds the permissible level, leading to adverse effects on human health and the ecosystem. The paper provides the optimized condition for the arsenic removal from the aqueous media using electrocoagulation, which is no additional reagents/chemicals, in situ generation of coagulants continuously, low energy consumption. The optimal conditions were found to be as follows: pH 7, electrolyte concentration NaCl 0.5 g L-1, current density 20 mA cm-2, and operational time 20 minutes, initial concentration of arsenic 50 mg L-1. Under the optimal condition, the maximum removal efficiency was 99.6%. Generally, the experimental results showed that the removal efficiency of As(V) from the aqueous medium was higher than 95% at pH = 4-8 ranges, 90% at the electrolyte concentration in the range of 0.25 g L-1 to 0.75 g L-1 , and 96% at the current density in the range of 15 mA cm-2 - 60 mA cm-2 respectively. Considering the variation of oxidation-reduction potential and pH during the electrocoagulation and FTIR spectra of solid residue, we found that As(V) was removed through the chemical precipitation (FeAsO4) and adsorption (Fe(OH)3×HAsO42-).
Усан орчноос As(V) ионы агуулгыг бууруулах электрокоагуляцийн зохистой нөхцөлийг тогтоох судалгаа
Хураангуй: Сүүлийн жилүүдэд эрдэс түүхий эдийн олборлолт, арсен агуулсан эрдэс чулуулгийн өгөршилөөр гадаргын болон гүний усан дахь арсены (As) агуулга хүлцэх агууламжаас ихсэх тохиолдлууд гарч байна. Энэ судалгааны ажлаар коагулянтаа орчинд нь тасралтгүй үүсгэдэг, нэмэлт урвалж шаарддаггүй, цахилгааны зарцуулалт багатай электрокоагуляцийн аргаар усан уусмал дахь As(V)-ыг тунадасжуулах зохистой нөхцөлийг тогтоох ажлыг хийж, үр дүнг спектрофотометр, индукцийн холбоост плазм-масс спектрометр, потенциометрийн аргаар тодорхойллоо. Зохистой нөхцөлийг тодорхойлох туршилтын дүнгээс харахад, усан орчноос As(V)-ын тунадасжуулалт рН=4-8-ын утганд >95%, электролитын концентрацийн 0.25 – 0.75 г/л мужид >90%, гүйдлийн нягтын 15 – 60 мА/см2 мужид >96% бүтээмжтэй байв. Уусмалын рН ~7, NaCl-ын концентраци 0.5 г/л, гүйдлийн нягт 20 мА/см2 үед 50 мг/л концентрацитай As(V)-ын зайлуулалт хамгийн их буюу 99.6% нь усан орчноос тунадасжиж байлаа. Исэлдэх ангижрах потенциал, рН-ын хугацаанаас хамаарах хамаарал, үүссэн тунадсын нил улаан туяаны спектрийн шинжилгээний үр дүнгээр, электрокоагуляциар As(V)-ын зайлуулалт нь химийн тунадасжилт (FeAsO4), адсорбц (Fe(OH)3×HAsO42-)-ийн процессоор явагддагийг тогтоолоо.
Түлхүүр үг: төмөр электрод, коагулянт, адсорбц, арсенат ион