{"title":"用远心光度计测量灯具光分布不确定度的估计","authors":"Iva Petrinska, K. Nikolova, Dilyan Ivanov, K. Georgiev","doi":"10.1109/BLJ.2019.8883663","DOIUrl":null,"url":null,"abstract":"The paper shows the methodology for estimation of the calibration uncertainty of a telecentric photometer. It shows in details all the possible sources of uncertainty that should be considered in a photometrical measurement, according to the construction of the equipment. In order to verify the experimental results, a verification has also been carried out – the light distribution of the test luminaire has also been measured with a previously calibrated mirror distributive gonio photometer","PeriodicalId":241572,"journal":{"name":"2019 Second Balkan Junior Conference on Lighting (Balkan Light Junior)","volume":"105 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Estimation of the uncertainty in measurement of light distribution of luminaires by means of telecentric photometer\",\"authors\":\"Iva Petrinska, K. Nikolova, Dilyan Ivanov, K. Georgiev\",\"doi\":\"10.1109/BLJ.2019.8883663\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper shows the methodology for estimation of the calibration uncertainty of a telecentric photometer. It shows in details all the possible sources of uncertainty that should be considered in a photometrical measurement, according to the construction of the equipment. In order to verify the experimental results, a verification has also been carried out – the light distribution of the test luminaire has also been measured with a previously calibrated mirror distributive gonio photometer\",\"PeriodicalId\":241572,\"journal\":{\"name\":\"2019 Second Balkan Junior Conference on Lighting (Balkan Light Junior)\",\"volume\":\"105 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 Second Balkan Junior Conference on Lighting (Balkan Light Junior)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BLJ.2019.8883663\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Second Balkan Junior Conference on Lighting (Balkan Light Junior)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BLJ.2019.8883663","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Estimation of the uncertainty in measurement of light distribution of luminaires by means of telecentric photometer
The paper shows the methodology for estimation of the calibration uncertainty of a telecentric photometer. It shows in details all the possible sources of uncertainty that should be considered in a photometrical measurement, according to the construction of the equipment. In order to verify the experimental results, a verification has also been carried out – the light distribution of the test luminaire has also been measured with a previously calibrated mirror distributive gonio photometer