七电平逆变器的故障检测与容错操作

Aquib Mehdi Naqvi, Pushkar Tripathi, S. Singh
{"title":"七电平逆变器的故障检测与容错操作","authors":"Aquib Mehdi Naqvi, Pushkar Tripathi, S. Singh","doi":"10.1109/PIECON56912.2023.10085776","DOIUrl":null,"url":null,"abstract":"Applications of multilevel inverters (MLIs) are increasing extensively. Despite many advantages of MLIs, poor reliability of MLIs is a major concern as MLIs consist of a large number of semiconductor switches. Fault-tolerant topologies provide the solution to this problem. In this paper, a fault detection and identification method is presented for a sevenlevel fault-tolerant inverter. This fault detection method is based on monitoring the total harmonic distortion (THD) in output voltage and average voltage of one cycle. After identification of the faulty switch, the switching sequence and switching angles are to be adjusted. The method of fault detection and identification is verified by simulation results.","PeriodicalId":182428,"journal":{"name":"2023 International Conference on Power, Instrumentation, Energy and Control (PIECON)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fault detection and fault-tolerant operation of a seven-level inverter\",\"authors\":\"Aquib Mehdi Naqvi, Pushkar Tripathi, S. Singh\",\"doi\":\"10.1109/PIECON56912.2023.10085776\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Applications of multilevel inverters (MLIs) are increasing extensively. Despite many advantages of MLIs, poor reliability of MLIs is a major concern as MLIs consist of a large number of semiconductor switches. Fault-tolerant topologies provide the solution to this problem. In this paper, a fault detection and identification method is presented for a sevenlevel fault-tolerant inverter. This fault detection method is based on monitoring the total harmonic distortion (THD) in output voltage and average voltage of one cycle. After identification of the faulty switch, the switching sequence and switching angles are to be adjusted. The method of fault detection and identification is verified by simulation results.\",\"PeriodicalId\":182428,\"journal\":{\"name\":\"2023 International Conference on Power, Instrumentation, Energy and Control (PIECON)\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 International Conference on Power, Instrumentation, Energy and Control (PIECON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PIECON56912.2023.10085776\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 International Conference on Power, Instrumentation, Energy and Control (PIECON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PIECON56912.2023.10085776","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

多电平逆变器的应用日益广泛。尽管mli具有许多优点,但由于mli由大量半导体开关组成,因此可靠性差是一个主要问题。容错拓扑为这个问题提供了解决方案。提出了一种针对七电平容错逆变器的故障检测与识别方法。这种故障检测方法是基于监测输出电压和一个周期平均电压的总谐波失真(THD)。确认故障开关后,调整开关顺序和开关角度。仿真结果验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fault detection and fault-tolerant operation of a seven-level inverter
Applications of multilevel inverters (MLIs) are increasing extensively. Despite many advantages of MLIs, poor reliability of MLIs is a major concern as MLIs consist of a large number of semiconductor switches. Fault-tolerant topologies provide the solution to this problem. In this paper, a fault detection and identification method is presented for a sevenlevel fault-tolerant inverter. This fault detection method is based on monitoring the total harmonic distortion (THD) in output voltage and average voltage of one cycle. After identification of the faulty switch, the switching sequence and switching angles are to be adjusted. The method of fault detection and identification is verified by simulation results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信