NCSRD串联加速器设施的快中子活化分析:预测和优化

Z. Bari, S. Chasapoglou, A. Kalamara, T. Vasilopoulou, M. Axiotis, A. Lagoyannis, M. Kokkoris, R. Vlastou, I. Stamatelatos
{"title":"NCSRD串联加速器设施的快中子活化分析:预测和优化","authors":"Z. Bari, S. Chasapoglou, A. Kalamara, T. Vasilopoulou, M. Axiotis, A. Lagoyannis, M. Kokkoris, R. Vlastou, I. Stamatelatos","doi":"10.12681/hnps.4798","DOIUrl":null,"url":null,"abstract":"Neutron Activation Analysis Prognosis and Optimization (NAAPRO) code was applied for the prognosis of the activation products, their activities, the number of counts recorded in the detector, the minimum detection limits as well as the gamma spectrum obtained in fast neutron activation analysis experiments. Simulations were performed for geological and biological reference materials irradiated with 14 MeV neutrons at the 5.5 MV NCSRD tandem accelerator facility. The results of the study demonstrated the fast neutron analytical capabilities of the accelerator and, moreover, allowed for the optimization of the FNAA parameters, while avoiding the performance of difficult and time-consuming experimental tests at the accelerator facility.","PeriodicalId":262803,"journal":{"name":"HNPS Advances in Nuclear Physics","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fast Neutron Activation Analysis at the NCSRD Tandem Accelerator facility: Prognosis and Optimization\",\"authors\":\"Z. Bari, S. Chasapoglou, A. Kalamara, T. Vasilopoulou, M. Axiotis, A. Lagoyannis, M. Kokkoris, R. Vlastou, I. Stamatelatos\",\"doi\":\"10.12681/hnps.4798\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Neutron Activation Analysis Prognosis and Optimization (NAAPRO) code was applied for the prognosis of the activation products, their activities, the number of counts recorded in the detector, the minimum detection limits as well as the gamma spectrum obtained in fast neutron activation analysis experiments. Simulations were performed for geological and biological reference materials irradiated with 14 MeV neutrons at the 5.5 MV NCSRD tandem accelerator facility. The results of the study demonstrated the fast neutron analytical capabilities of the accelerator and, moreover, allowed for the optimization of the FNAA parameters, while avoiding the performance of difficult and time-consuming experimental tests at the accelerator facility.\",\"PeriodicalId\":262803,\"journal\":{\"name\":\"HNPS Advances in Nuclear Physics\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"HNPS Advances in Nuclear Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12681/hnps.4798\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"HNPS Advances in Nuclear Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12681/hnps.4798","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

应用NAAPRO(中子活化分析预测与优化)程序对快中子活化分析实验中得到的活化产物、活度、检测器记录的计数数、最小检出限以及伽马谱进行预测。在5.5 MV NCSRD串联加速器上,对14 MeV中子辐照的地质和生物标准物质进行了模拟。研究结果证明了该加速器的快中子分析能力,并且允许优化FNAA参数,同时避免在加速器设施中进行困难和耗时的实验测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fast Neutron Activation Analysis at the NCSRD Tandem Accelerator facility: Prognosis and Optimization
Neutron Activation Analysis Prognosis and Optimization (NAAPRO) code was applied for the prognosis of the activation products, their activities, the number of counts recorded in the detector, the minimum detection limits as well as the gamma spectrum obtained in fast neutron activation analysis experiments. Simulations were performed for geological and biological reference materials irradiated with 14 MeV neutrons at the 5.5 MV NCSRD tandem accelerator facility. The results of the study demonstrated the fast neutron analytical capabilities of the accelerator and, moreover, allowed for the optimization of the FNAA parameters, while avoiding the performance of difficult and time-consuming experimental tests at the accelerator facility.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信