级联系统的通用阻抗/导纳稳定性判据

Liu Fangcheng, Liu Jinjun, Zhang Bin, Zhang Hao-dong, H. S. Ul
{"title":"级联系统的通用阻抗/导纳稳定性判据","authors":"Liu Fangcheng, Liu Jinjun, Zhang Bin, Zhang Hao-dong, H. S. Ul","doi":"10.1109/ECCE-ASIA.2013.6579131","DOIUrl":null,"url":null,"abstract":"Impedance-based stability criterions have been proved to be a very effective tool for the stability assessment when considering interaction between different modules. Two different stability criterions in the form of impedance ratio as Zo/Zi and Zi/Zo have been proposed for different system. However, the intrinsic relationship of these criterions has not been fully discussed. In this paper, the terminal characteristics of single module are focused. The physical meanings of terminal impedance and admittance are explained. Based on the physical understanding, different mathematical methods are derived for the stability prediction in cascade system. Through comparison, the advantage of proposed impedance/admittance stability criterion is analyzed as its convenience in mathematical calculation. As analyzed, the proposed impedance/admittance criterion can be used in the cascade system where existing impedance ratio type criterion can be used and the physical meaning of proposed criterion is clearer.","PeriodicalId":301487,"journal":{"name":"2013 IEEE ECCE Asia Downunder","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"General impedance/admittance stability criterion for cascade system\",\"authors\":\"Liu Fangcheng, Liu Jinjun, Zhang Bin, Zhang Hao-dong, H. S. Ul\",\"doi\":\"10.1109/ECCE-ASIA.2013.6579131\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Impedance-based stability criterions have been proved to be a very effective tool for the stability assessment when considering interaction between different modules. Two different stability criterions in the form of impedance ratio as Zo/Zi and Zi/Zo have been proposed for different system. However, the intrinsic relationship of these criterions has not been fully discussed. In this paper, the terminal characteristics of single module are focused. The physical meanings of terminal impedance and admittance are explained. Based on the physical understanding, different mathematical methods are derived for the stability prediction in cascade system. Through comparison, the advantage of proposed impedance/admittance stability criterion is analyzed as its convenience in mathematical calculation. As analyzed, the proposed impedance/admittance criterion can be used in the cascade system where existing impedance ratio type criterion can be used and the physical meaning of proposed criterion is clearer.\",\"PeriodicalId\":301487,\"journal\":{\"name\":\"2013 IEEE ECCE Asia Downunder\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE ECCE Asia Downunder\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECCE-ASIA.2013.6579131\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE ECCE Asia Downunder","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE-ASIA.2013.6579131","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

基于阻抗的稳定性判据已被证明是一种非常有效的稳定性评估工具,可以考虑不同模块之间的相互作用。针对不同的系统,分别提出了Zo/Zi和Zi/Zo两种阻抗比形式的稳定性判据。然而,这些准则之间的内在关系尚未得到充分讨论。本文重点研究了单模块的终端特性。说明了终端阻抗和导纳的物理意义。在物理认识的基础上,推导出了不同的串级系统稳定性预测的数学方法。通过比较,分析了所提出的阻抗导纳稳定性判据在数学计算上的便捷性。经分析,所提出的阻抗/导纳判据可用于级联系统,在级联系统中可以使用现有的阻抗比型判据,并且所提出的判据的物理意义更清晰。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
General impedance/admittance stability criterion for cascade system
Impedance-based stability criterions have been proved to be a very effective tool for the stability assessment when considering interaction between different modules. Two different stability criterions in the form of impedance ratio as Zo/Zi and Zi/Zo have been proposed for different system. However, the intrinsic relationship of these criterions has not been fully discussed. In this paper, the terminal characteristics of single module are focused. The physical meanings of terminal impedance and admittance are explained. Based on the physical understanding, different mathematical methods are derived for the stability prediction in cascade system. Through comparison, the advantage of proposed impedance/admittance stability criterion is analyzed as its convenience in mathematical calculation. As analyzed, the proposed impedance/admittance criterion can be used in the cascade system where existing impedance ratio type criterion can be used and the physical meaning of proposed criterion is clearer.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信