基于粒子群优化的支持向量机微震首点自动拾取方法

Tieniu Li, Binxin Hu, Zengrong Sun, Feng Zhu, Hua Zhang, Quancheng Yang
{"title":"基于粒子群优化的支持向量机微震首点自动拾取方法","authors":"Tieniu Li, Binxin Hu, Zengrong Sun, Feng Zhu, Hua Zhang, Quancheng Yang","doi":"10.1117/12.2667714","DOIUrl":null,"url":null,"abstract":"Automatic and accurate arrival time pickup of microseismic first-arrival waves is an important prerequisite for high precision microseismic source location. Aiming at the low efficiency of the traditional manual pickup method and the low accuracy of the long, short window energy ratio (STA/LTA) method commonly used in automatic pickup for low signal-to-noise ratio signals, an automatic picking method of microseismic first arrival based on support vector machine based on particle swarm optimization is proposed. Firstly, according to the amplitude and energy of microseismic signal and the energy ratio of adjacent time, the signals are marked with different categories. Then the parameters are optimized by particle swarm optimization algorithm to construct the support vector machine model of microseismic first-arrival. Finally, the data is substituted to extract the microseismic first-arrival. The experiment is carried out with the microseismic monitoring data of underground roadway in a gold mine. The experimental results show that, under the condition of low SIGNal-to-noise ratio, the picking accuracy of the proposed method is 96.4%, the average pickup error is 3.9ms, and the picking accuracy and accuracy are better than STA/LTA method.","PeriodicalId":345723,"journal":{"name":"Fifth International Conference on Computer Information Science and Artificial Intelligence","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Automatic picking method of microseismic first arrival based on support vector machine based on particle swarm optimization\",\"authors\":\"Tieniu Li, Binxin Hu, Zengrong Sun, Feng Zhu, Hua Zhang, Quancheng Yang\",\"doi\":\"10.1117/12.2667714\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Automatic and accurate arrival time pickup of microseismic first-arrival waves is an important prerequisite for high precision microseismic source location. Aiming at the low efficiency of the traditional manual pickup method and the low accuracy of the long, short window energy ratio (STA/LTA) method commonly used in automatic pickup for low signal-to-noise ratio signals, an automatic picking method of microseismic first arrival based on support vector machine based on particle swarm optimization is proposed. Firstly, according to the amplitude and energy of microseismic signal and the energy ratio of adjacent time, the signals are marked with different categories. Then the parameters are optimized by particle swarm optimization algorithm to construct the support vector machine model of microseismic first-arrival. Finally, the data is substituted to extract the microseismic first-arrival. The experiment is carried out with the microseismic monitoring data of underground roadway in a gold mine. The experimental results show that, under the condition of low SIGNal-to-noise ratio, the picking accuracy of the proposed method is 96.4%, the average pickup error is 3.9ms, and the picking accuracy and accuracy are better than STA/LTA method.\",\"PeriodicalId\":345723,\"journal\":{\"name\":\"Fifth International Conference on Computer Information Science and Artificial Intelligence\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fifth International Conference on Computer Information Science and Artificial Intelligence\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2667714\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fifth International Conference on Computer Information Science and Artificial Intelligence","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2667714","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

微震初到波的自动准确到达时间采集是实现高精度微震源定位的重要前提。针对传统人工采集方法效率低、低信噪比信号自动采集常用的长、短窗口能量比(STA/LTA)方法精度低的问题,提出了一种基于粒子群优化的支持向量机微震初到自动采集方法。首先,根据微震信号的振幅和能量以及相邻时间的能量比,对微震信号进行分类;然后利用粒子群优化算法对参数进行优化,构建微地震初到支持向量机模型。最后,代入数据提取微震初至。利用某金矿地下巷道微震监测资料进行了试验研究。实验结果表明,在低信噪比条件下,该方法的拾取精度为96.4%,平均拾取误差为3.9ms,拾取精度和精度均优于STA/LTA方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Automatic picking method of microseismic first arrival based on support vector machine based on particle swarm optimization
Automatic and accurate arrival time pickup of microseismic first-arrival waves is an important prerequisite for high precision microseismic source location. Aiming at the low efficiency of the traditional manual pickup method and the low accuracy of the long, short window energy ratio (STA/LTA) method commonly used in automatic pickup for low signal-to-noise ratio signals, an automatic picking method of microseismic first arrival based on support vector machine based on particle swarm optimization is proposed. Firstly, according to the amplitude and energy of microseismic signal and the energy ratio of adjacent time, the signals are marked with different categories. Then the parameters are optimized by particle swarm optimization algorithm to construct the support vector machine model of microseismic first-arrival. Finally, the data is substituted to extract the microseismic first-arrival. The experiment is carried out with the microseismic monitoring data of underground roadway in a gold mine. The experimental results show that, under the condition of low SIGNal-to-noise ratio, the picking accuracy of the proposed method is 96.4%, the average pickup error is 3.9ms, and the picking accuracy and accuracy are better than STA/LTA method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信