生物阻抗谱在动物模型中监测流体状态的评价

S. Weyer, Lisa Röthlingshöfer, M. Walter, S. Leonhardt, R. Bensberg
{"title":"生物阻抗谱在动物模型中监测流体状态的评价","authors":"S. Weyer, Lisa Röthlingshöfer, M. Walter, S. Leonhardt, R. Bensberg","doi":"10.1109/BSN.2012.25","DOIUrl":null,"url":null,"abstract":"This study investigates the feasibility of using bioelectrical impedance measurements to detect the body fluid status. The multi-frequency impedance measurements were performed in combination with an animal experiment with five female pigs. For this purpose, the fluid balances of these animals, which were connected to an extracorporeal membrane oxygenation, were recorded. The ECMO circuit needs a high blood flow from the venous system and in order to avoid vasoconstriction in the femoral vein, blood-thinning infusions were injected. The quantity of injected fluid and the quantity of urine were recorded to monitor the fluid balance of each animal. These balances were compared with the intracellular and extra cellular tissue resistance, which was measured by bioelectrical-impedance spectroscopy. The experimental results strongly support the clinical benefit of the BIS for the assessment of changes in the hydration status.","PeriodicalId":101720,"journal":{"name":"2012 Ninth International Conference on Wearable and Implantable Body Sensor Networks","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Evaluation of Bioimpedance Spectroscopy for the Monitoring of the Fluid Status in an Animal Model\",\"authors\":\"S. Weyer, Lisa Röthlingshöfer, M. Walter, S. Leonhardt, R. Bensberg\",\"doi\":\"10.1109/BSN.2012.25\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study investigates the feasibility of using bioelectrical impedance measurements to detect the body fluid status. The multi-frequency impedance measurements were performed in combination with an animal experiment with five female pigs. For this purpose, the fluid balances of these animals, which were connected to an extracorporeal membrane oxygenation, were recorded. The ECMO circuit needs a high blood flow from the venous system and in order to avoid vasoconstriction in the femoral vein, blood-thinning infusions were injected. The quantity of injected fluid and the quantity of urine were recorded to monitor the fluid balance of each animal. These balances were compared with the intracellular and extra cellular tissue resistance, which was measured by bioelectrical-impedance spectroscopy. The experimental results strongly support the clinical benefit of the BIS for the assessment of changes in the hydration status.\",\"PeriodicalId\":101720,\"journal\":{\"name\":\"2012 Ninth International Conference on Wearable and Implantable Body Sensor Networks\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 Ninth International Conference on Wearable and Implantable Body Sensor Networks\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BSN.2012.25\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Ninth International Conference on Wearable and Implantable Body Sensor Networks","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BSN.2012.25","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本研究探讨了利用生物电阻抗测量来检测体液状态的可行性。多频阻抗测量结合5头母猪的动物实验进行。为此,记录了这些动物的体液平衡,这些动物与体外膜氧合相连接。ECMO回路需要来自静脉系统的高血流量,为了避免股静脉血管收缩,注射了血液稀释剂。记录注射液量和尿量,监测每只动物的体液平衡。这些平衡与细胞内和细胞外组织阻力进行比较,后者是通过生物电阻抗谱测量的。实验结果有力地支持BIS用于评估水合状态变化的临床益处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of Bioimpedance Spectroscopy for the Monitoring of the Fluid Status in an Animal Model
This study investigates the feasibility of using bioelectrical impedance measurements to detect the body fluid status. The multi-frequency impedance measurements were performed in combination with an animal experiment with five female pigs. For this purpose, the fluid balances of these animals, which were connected to an extracorporeal membrane oxygenation, were recorded. The ECMO circuit needs a high blood flow from the venous system and in order to avoid vasoconstriction in the femoral vein, blood-thinning infusions were injected. The quantity of injected fluid and the quantity of urine were recorded to monitor the fluid balance of each animal. These balances were compared with the intracellular and extra cellular tissue resistance, which was measured by bioelectrical-impedance spectroscopy. The experimental results strongly support the clinical benefit of the BIS for the assessment of changes in the hydration status.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信