逆变器高开关频率对温度传感器射频干扰的影响

S. Voon, J. Kong, R. Gobbi
{"title":"逆变器高开关频率对温度传感器射频干扰的影响","authors":"S. Voon, J. Kong, R. Gobbi","doi":"10.1109/PECON.2003.1437422","DOIUrl":null,"url":null,"abstract":"Variable speed drives (VSD) is widely used in the industry because of the cost saving, reliability and easy control characteristics. VSD uses high switching frequency to reduce harmonics which causes disruption in motor performances. The phenomenon of EMI emissions from electronic devices has adverse effects on the accuracy of the data readings. This is very obvious in the process of converting and inverting the current signal where there are harmonics. The RFI component of EMI will couple either through conduction and/or radiation to the victims, i.e. temperature sensor. This may cause inconsistent changes of temperature reading instigating a premature shut down and costing millions of dollar in damages in automated industries. This paper mainly focuses on the total effect of the RFI which is due to the high switching frequency of the inverter on the reading of the temperature sensor by going through a series of experimentation and simulation steps.","PeriodicalId":136640,"journal":{"name":"Proceedings. National Power Engineering Conference, 2003. PECon 2003.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Effect of radio frequency interference (RFI) due to high switching frequency of inverter on temperature sensor\",\"authors\":\"S. Voon, J. Kong, R. Gobbi\",\"doi\":\"10.1109/PECON.2003.1437422\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Variable speed drives (VSD) is widely used in the industry because of the cost saving, reliability and easy control characteristics. VSD uses high switching frequency to reduce harmonics which causes disruption in motor performances. The phenomenon of EMI emissions from electronic devices has adverse effects on the accuracy of the data readings. This is very obvious in the process of converting and inverting the current signal where there are harmonics. The RFI component of EMI will couple either through conduction and/or radiation to the victims, i.e. temperature sensor. This may cause inconsistent changes of temperature reading instigating a premature shut down and costing millions of dollar in damages in automated industries. This paper mainly focuses on the total effect of the RFI which is due to the high switching frequency of the inverter on the reading of the temperature sensor by going through a series of experimentation and simulation steps.\",\"PeriodicalId\":136640,\"journal\":{\"name\":\"Proceedings. National Power Engineering Conference, 2003. PECon 2003.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings. National Power Engineering Conference, 2003. PECon 2003.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECON.2003.1437422\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. National Power Engineering Conference, 2003. PECon 2003.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECON.2003.1437422","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

变速驱动器(VSD)由于具有成本节约、可靠性高、易于控制等特点,在工业上得到了广泛的应用。VSD使用高开关频率来减少导致电机性能中断的谐波。电子设备产生的电磁干扰现象对数据读取的准确性有不利影响。这在有谐波的电流信号的转换和反相过程中是非常明显的。电磁干扰的RFI组件将通过传导和/或辐射耦合到受害者,即温度传感器。这可能会导致温度读数不一致的变化,从而导致过早关闭,并在自动化工业中造成数百万美元的损失。本文主要通过一系列的实验和仿真步骤来研究逆变器的高开关频率对温度传感器读数的RFI的总影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of radio frequency interference (RFI) due to high switching frequency of inverter on temperature sensor
Variable speed drives (VSD) is widely used in the industry because of the cost saving, reliability and easy control characteristics. VSD uses high switching frequency to reduce harmonics which causes disruption in motor performances. The phenomenon of EMI emissions from electronic devices has adverse effects on the accuracy of the data readings. This is very obvious in the process of converting and inverting the current signal where there are harmonics. The RFI component of EMI will couple either through conduction and/or radiation to the victims, i.e. temperature sensor. This may cause inconsistent changes of temperature reading instigating a premature shut down and costing millions of dollar in damages in automated industries. This paper mainly focuses on the total effect of the RFI which is due to the high switching frequency of the inverter on the reading of the temperature sensor by going through a series of experimentation and simulation steps.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信