Yingwei Huang, M. Chapariha, S. Ebrahimi, Navid Amiri, J. Jatskevich
{"title":"集成交直流电源系统的SFA和gam型动态相量建模接口","authors":"Yingwei Huang, M. Chapariha, S. Ebrahimi, Navid Amiri, J. Jatskevich","doi":"10.1109/PESGM.2016.7741274","DOIUrl":null,"url":null,"abstract":"This paper focuses on the modeling of integrated ac-dc backup and generation power systems, which has received increasing attention due to the emergence of microgrids and distributed generations. The conventional shifted-frequency analysis (SFA) type dynamic phasors (DPs) assume a bandpass spectrum of power system signals, and thus are only suitable to model system components wherein the 60Hz fundamental frequency is dominant. To account for high-order harmonics of interest in ac-dc systems, this paper considers another type of DPs based on the generalized averaging method (GAM), and proposes a possible interface between the SFA- and GAM-type DP models. Computer studies demonstrate that the proposed DP interface allows for accurate simulations of both fundamental frequency components and high-order harmonics in integrated ac-dc power systems, while providing significant numerical advantages over the conventional time-domain detailed models.","PeriodicalId":155315,"journal":{"name":"2016 IEEE Power and Energy Society General Meeting (PESGM)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Interfacing SFA- and GAM-type dynamic phasors for modeling of integrated AC-DC power systems\",\"authors\":\"Yingwei Huang, M. Chapariha, S. Ebrahimi, Navid Amiri, J. Jatskevich\",\"doi\":\"10.1109/PESGM.2016.7741274\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper focuses on the modeling of integrated ac-dc backup and generation power systems, which has received increasing attention due to the emergence of microgrids and distributed generations. The conventional shifted-frequency analysis (SFA) type dynamic phasors (DPs) assume a bandpass spectrum of power system signals, and thus are only suitable to model system components wherein the 60Hz fundamental frequency is dominant. To account for high-order harmonics of interest in ac-dc systems, this paper considers another type of DPs based on the generalized averaging method (GAM), and proposes a possible interface between the SFA- and GAM-type DP models. Computer studies demonstrate that the proposed DP interface allows for accurate simulations of both fundamental frequency components and high-order harmonics in integrated ac-dc power systems, while providing significant numerical advantages over the conventional time-domain detailed models.\",\"PeriodicalId\":155315,\"journal\":{\"name\":\"2016 IEEE Power and Energy Society General Meeting (PESGM)\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Power and Energy Society General Meeting (PESGM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESGM.2016.7741274\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Power and Energy Society General Meeting (PESGM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM.2016.7741274","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Interfacing SFA- and GAM-type dynamic phasors for modeling of integrated AC-DC power systems
This paper focuses on the modeling of integrated ac-dc backup and generation power systems, which has received increasing attention due to the emergence of microgrids and distributed generations. The conventional shifted-frequency analysis (SFA) type dynamic phasors (DPs) assume a bandpass spectrum of power system signals, and thus are only suitable to model system components wherein the 60Hz fundamental frequency is dominant. To account for high-order harmonics of interest in ac-dc systems, this paper considers another type of DPs based on the generalized averaging method (GAM), and proposes a possible interface between the SFA- and GAM-type DP models. Computer studies demonstrate that the proposed DP interface allows for accurate simulations of both fundamental frequency components and high-order harmonics in integrated ac-dc power systems, while providing significant numerical advantages over the conventional time-domain detailed models.