CFRP预应力混凝土灯柱

G. Terrasi, J. Lees
{"title":"CFRP预应力混凝土灯柱","authors":"G. Terrasi, J. Lees","doi":"10.14359/12858","DOIUrl":null,"url":null,"abstract":"Aspects of the design and installation of a novel carbon fibre reinforced polymer (CFRP) prestressed high strength concrete lighting column (Carbolith®) are presented. The tapered cylindrical columns have a nominal height of 8 m and contain an opening above the foundation to allow for the insertion of the lamp fuse box. The bending/torsion behaviour of a total of five full-scale prototype columns was tested in accordance with the relevant European standards (EN). In the experimental programme, the location of the fuse box opening relative to the loading direction was varied. All five poles fulfilled the EN serviceability and ultimate limit state requirements for lighting columns in pedestrian and/or low speed lightly trafficked areas. This successful outcome has lead to the first field application of the CFRP prestressed concrete lighting columns.","PeriodicalId":354815,"journal":{"name":"SP-215: Field Applications of FRP Reinforcement: Case Studies","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"CFRP Prestressed Concrete Lighting Columns\",\"authors\":\"G. Terrasi, J. Lees\",\"doi\":\"10.14359/12858\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aspects of the design and installation of a novel carbon fibre reinforced polymer (CFRP) prestressed high strength concrete lighting column (Carbolith®) are presented. The tapered cylindrical columns have a nominal height of 8 m and contain an opening above the foundation to allow for the insertion of the lamp fuse box. The bending/torsion behaviour of a total of five full-scale prototype columns was tested in accordance with the relevant European standards (EN). In the experimental programme, the location of the fuse box opening relative to the loading direction was varied. All five poles fulfilled the EN serviceability and ultimate limit state requirements for lighting columns in pedestrian and/or low speed lightly trafficked areas. This successful outcome has lead to the first field application of the CFRP prestressed concrete lighting columns.\",\"PeriodicalId\":354815,\"journal\":{\"name\":\"SP-215: Field Applications of FRP Reinforcement: Case Studies\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SP-215: Field Applications of FRP Reinforcement: Case Studies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14359/12858\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SP-215: Field Applications of FRP Reinforcement: Case Studies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14359/12858","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

介绍了一种新型碳纤维增强聚合物(CFRP)预应力高强度混凝土照明柱(Carbolith®)的设计和安装。锥形圆柱柱的标称高度为8米,在基础上方有一个开口,允许插入灯丝盒。根据相关的欧洲标准(EN),对总共五个全尺寸原型柱的弯曲/扭转性能进行了测试。在实验程序中,保险丝盒开口相对于加载方向的位置发生了变化。所有五个灯杆都符合EN的可使用性和行人和/或低速交通区域照明柱的极限状态要求。这一成功成果为CFRP预应力混凝土照明柱的首次现场应用奠定了基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
CFRP Prestressed Concrete Lighting Columns
Aspects of the design and installation of a novel carbon fibre reinforced polymer (CFRP) prestressed high strength concrete lighting column (Carbolith®) are presented. The tapered cylindrical columns have a nominal height of 8 m and contain an opening above the foundation to allow for the insertion of the lamp fuse box. The bending/torsion behaviour of a total of five full-scale prototype columns was tested in accordance with the relevant European standards (EN). In the experimental programme, the location of the fuse box opening relative to the loading direction was varied. All five poles fulfilled the EN serviceability and ultimate limit state requirements for lighting columns in pedestrian and/or low speed lightly trafficked areas. This successful outcome has lead to the first field application of the CFRP prestressed concrete lighting columns.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信