B. Kallstrand, D. Borg, L. Walfridsson, K. Johansson, C. Doiron, Fredrik Falth, M. Saltzer
{"title":"高压直流电缆终端周围的直流场分布","authors":"B. Kallstrand, D. Borg, L. Walfridsson, K. Johansson, C. Doiron, Fredrik Falth, M. Saltzer","doi":"10.1109/CEIDP.2015.7352109","DOIUrl":null,"url":null,"abstract":"DC field measurements of the electric field around a cable termination have been performed. The field variation along the surface as well as its time development after voltage application is studied. The agreement between measured and simulated results is relatively good, for short times after voltage application. After longer time, deviations from the simulated results occur. Possible reasons for this discrepancy are discussed.","PeriodicalId":432404,"journal":{"name":"2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"DC field distribution around an HVDC cable termination\",\"authors\":\"B. Kallstrand, D. Borg, L. Walfridsson, K. Johansson, C. Doiron, Fredrik Falth, M. Saltzer\",\"doi\":\"10.1109/CEIDP.2015.7352109\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"DC field measurements of the electric field around a cable termination have been performed. The field variation along the surface as well as its time development after voltage application is studied. The agreement between measured and simulated results is relatively good, for short times after voltage application. After longer time, deviations from the simulated results occur. Possible reasons for this discrepancy are discussed.\",\"PeriodicalId\":432404,\"journal\":{\"name\":\"2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2015.7352109\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2015.7352109","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
DC field distribution around an HVDC cable termination
DC field measurements of the electric field around a cable termination have been performed. The field variation along the surface as well as its time development after voltage application is studied. The agreement between measured and simulated results is relatively good, for short times after voltage application. After longer time, deviations from the simulated results occur. Possible reasons for this discrepancy are discussed.