0. 用于肌电生物医学信号处理的4V,低功耗GmC集成商和带通滤波器设计

Veerayya Javvaji, Sarada Musala
{"title":"0. 用于肌电生物医学信号处理的4V,低功耗GmC集成商和带通滤波器设计","authors":"Veerayya Javvaji, Sarada Musala","doi":"10.1109/ICPEDC47771.2019.9036556","DOIUrl":null,"url":null,"abstract":"This paper presents a novel 0.4 V $G_{m}\\mathrm{C}$ integrator design approach and fourth order bandpass filter design for EMG biomedical applications with high DC gain and and low power consumption. The filter and integrator are implemented with a new architecture in 180nm CMOS process. By using negative resistance in proposed integrator the response can be controllable. The negative resistance in this paper is implemented with Operational Trans Conductance Amplifier(OTA) The response of proposed integrator is close to ideal integrator behavior.The OTA used in this work is operated with 0.4 V supply and bulk driven structure. The maximum power consumption of integrator is 45 nW and cut off frequency is 160 Hz. The fourth order bandpass filter is consumes 117nW power with bandwidth 260 Hz. The dynamic range of the filter is 63dB.","PeriodicalId":426923,"journal":{"name":"2019 2nd International Conference on Power and Embedded Drive Control (ICPEDC)","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"0. 4V, Low Power GmC Integrator And Bandpass Filter Design For EMG Bio Medical Signal Processing\",\"authors\":\"Veerayya Javvaji, Sarada Musala\",\"doi\":\"10.1109/ICPEDC47771.2019.9036556\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a novel 0.4 V $G_{m}\\\\mathrm{C}$ integrator design approach and fourth order bandpass filter design for EMG biomedical applications with high DC gain and and low power consumption. The filter and integrator are implemented with a new architecture in 180nm CMOS process. By using negative resistance in proposed integrator the response can be controllable. The negative resistance in this paper is implemented with Operational Trans Conductance Amplifier(OTA) The response of proposed integrator is close to ideal integrator behavior.The OTA used in this work is operated with 0.4 V supply and bulk driven structure. The maximum power consumption of integrator is 45 nW and cut off frequency is 160 Hz. The fourth order bandpass filter is consumes 117nW power with bandwidth 260 Hz. The dynamic range of the filter is 63dB.\",\"PeriodicalId\":426923,\"journal\":{\"name\":\"2019 2nd International Conference on Power and Embedded Drive Control (ICPEDC)\",\"volume\":\"67 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 2nd International Conference on Power and Embedded Drive Control (ICPEDC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPEDC47771.2019.9036556\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 2nd International Conference on Power and Embedded Drive Control (ICPEDC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPEDC47771.2019.9036556","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一种新颖的0.4 V $G_{m}\math {C}$积分器设计方法和四阶带通滤波器设计,用于高直流增益和低功耗的肌电生物医学应用。滤波器和积分器采用180nm CMOS工艺的新架构实现。通过在积分器中使用负电阻,可以实现响应的可控。本文采用运算跨导放大器(OTA)实现负电阻,所提积分器的响应接近理想积分器行为。本工作中使用的OTA采用0.4 V电源和散装驱动结构。积分器的最大功耗为45nw,截止频率为160hz。四阶带通滤波器功耗为117nW,带宽为260hz。滤波器的动态范围为63dB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
0. 4V, Low Power GmC Integrator And Bandpass Filter Design For EMG Bio Medical Signal Processing
This paper presents a novel 0.4 V $G_{m}\mathrm{C}$ integrator design approach and fourth order bandpass filter design for EMG biomedical applications with high DC gain and and low power consumption. The filter and integrator are implemented with a new architecture in 180nm CMOS process. By using negative resistance in proposed integrator the response can be controllable. The negative resistance in this paper is implemented with Operational Trans Conductance Amplifier(OTA) The response of proposed integrator is close to ideal integrator behavior.The OTA used in this work is operated with 0.4 V supply and bulk driven structure. The maximum power consumption of integrator is 45 nW and cut off frequency is 160 Hz. The fourth order bandpass filter is consumes 117nW power with bandwidth 260 Hz. The dynamic range of the filter is 63dB.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信