Z. Piątek, T. Szczegielniak, D. Kusiak, P. Jabłoński
{"title":"屏蔽三相母线系统的磁场","authors":"Z. Piątek, T. Szczegielniak, D. Kusiak, P. Jabłoński","doi":"10.1109/CPEE.2015.7333361","DOIUrl":null,"url":null,"abstract":"The paper presents the measurement results of the magnetic field in a shielded three-phase busbar system manufactured by Holduct Mysłowice. The measurements were performed with use of a specific non-directional magnetic field probe. In addition, also theoretical computations were done with use of finite elements. The results roughly agree, but at some probing points the differences are considerable, probably due to inaccurate positioning the probe between the bus bars.","PeriodicalId":135123,"journal":{"name":"2015 16th International Conference on Computational Problems of Electrical Engineering (CPEE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Magnetic field of a shielded three-phase busbar system\",\"authors\":\"Z. Piątek, T. Szczegielniak, D. Kusiak, P. Jabłoński\",\"doi\":\"10.1109/CPEE.2015.7333361\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents the measurement results of the magnetic field in a shielded three-phase busbar system manufactured by Holduct Mysłowice. The measurements were performed with use of a specific non-directional magnetic field probe. In addition, also theoretical computations were done with use of finite elements. The results roughly agree, but at some probing points the differences are considerable, probably due to inaccurate positioning the probe between the bus bars.\",\"PeriodicalId\":135123,\"journal\":{\"name\":\"2015 16th International Conference on Computational Problems of Electrical Engineering (CPEE)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 16th International Conference on Computational Problems of Electrical Engineering (CPEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEE.2015.7333361\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 16th International Conference on Computational Problems of Electrical Engineering (CPEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEE.2015.7333361","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Magnetic field of a shielded three-phase busbar system
The paper presents the measurement results of the magnetic field in a shielded three-phase busbar system manufactured by Holduct Mysłowice. The measurements were performed with use of a specific non-directional magnetic field probe. In addition, also theoretical computations were done with use of finite elements. The results roughly agree, but at some probing points the differences are considerable, probably due to inaccurate positioning the probe between the bus bars.