{"title":"Gis实验室和现场试验中隔离开关的切换","authors":"E. Kynasi, H. Luehrmann","doi":"10.1109/TPAS.1985.318823","DOIUrl":null,"url":null,"abstract":"Field tests on the subject switching of capacitive currents with disconnectors were carried out in a 420 kV Gas Insulated Substation (GIS). The overvoltages and transients occurring were recorded at several points within the GIS while different disconnectors were operated.","PeriodicalId":227345,"journal":{"name":"IEEE Transactions on Power Apparatus and Systems","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1985-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Switching Of Disconnectros In Gis Laboratory And Field Tests\",\"authors\":\"E. Kynasi, H. Luehrmann\",\"doi\":\"10.1109/TPAS.1985.318823\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Field tests on the subject switching of capacitive currents with disconnectors were carried out in a 420 kV Gas Insulated Substation (GIS). The overvoltages and transients occurring were recorded at several points within the GIS while different disconnectors were operated.\",\"PeriodicalId\":227345,\"journal\":{\"name\":\"IEEE Transactions on Power Apparatus and Systems\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Power Apparatus and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TPAS.1985.318823\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Power Apparatus and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TPAS.1985.318823","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在420千伏气体绝缘变电站(GIS)中进行了带隔离器的容性电流主体开关的现场试验。当操作不同的隔离器时,在GIS内的几个点记录过电压和瞬变。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Switching Of Disconnectros In Gis Laboratory And Field Tests
Field tests on the subject switching of capacitive currents with disconnectors were carried out in a 420 kV Gas Insulated Substation (GIS). The overvoltages and transients occurring were recorded at several points within the GIS while different disconnectors were operated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信