{"title":"并联输电线路对配电导线电磁干扰的研究及实际缓解措施","authors":"M. Shen, S. Shah, R. Eftekhari","doi":"10.1109/TDC.2014.6863407","DOIUrl":null,"url":null,"abstract":"The transmission line is normally built off-road due to the right of way requirements, while the distribution line is normally built on the road allowance because distribution customers are served from the road allowance. In order to connect remote renewable resources to transmission system in the vicinity, tens of kilometers of high voltage tap line is usually required. To minimize the cost and other issues in land and right of way acquisition, renewable energy developers prefer to use the existing structures jointly and route their HV tap line along the existing right of way. When HV tap line is overbuilt to share the same narrow right of way with distribution lines, it will induce voltages and currents on both phase and neutral conductors of existing distribution lines. Excessive induced voltage and current on distribution neutral and phase conductors may occur during normal operation, fault, and transient conditions of the transmission system. Detailed electromagnetic interference studies shall be conducted to assess the impact of overbuilt or parallel transmission line on the distribution system. This paper will discuss the phenomena of electromagnetic interference generated from HV tap line to the parallel distribution lines. Different practical mitigation solutions will be presented as well.","PeriodicalId":161074,"journal":{"name":"2014 IEEE PES T&D Conference and Exposition","volume":"87 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Study of electromagnetic interference on distribution conductors from parallel transmission line and practical mitigation solutions\",\"authors\":\"M. Shen, S. Shah, R. Eftekhari\",\"doi\":\"10.1109/TDC.2014.6863407\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The transmission line is normally built off-road due to the right of way requirements, while the distribution line is normally built on the road allowance because distribution customers are served from the road allowance. In order to connect remote renewable resources to transmission system in the vicinity, tens of kilometers of high voltage tap line is usually required. To minimize the cost and other issues in land and right of way acquisition, renewable energy developers prefer to use the existing structures jointly and route their HV tap line along the existing right of way. When HV tap line is overbuilt to share the same narrow right of way with distribution lines, it will induce voltages and currents on both phase and neutral conductors of existing distribution lines. Excessive induced voltage and current on distribution neutral and phase conductors may occur during normal operation, fault, and transient conditions of the transmission system. Detailed electromagnetic interference studies shall be conducted to assess the impact of overbuilt or parallel transmission line on the distribution system. This paper will discuss the phenomena of electromagnetic interference generated from HV tap line to the parallel distribution lines. Different practical mitigation solutions will be presented as well.\",\"PeriodicalId\":161074,\"journal\":{\"name\":\"2014 IEEE PES T&D Conference and Exposition\",\"volume\":\"87 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-04-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE PES T&D Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TDC.2014.6863407\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE PES T&D Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC.2014.6863407","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

由于路权的要求,输电线路通常建在非公路上,而配电线路通常建在道路余量上,因为配电客户是从道路余量上服务的。为了将远程再生能源接入附近的输电系统,通常需要数十公里的高压分接线路。为了最大限度地降低土地和路权获取的成本和其他问题,可再生能源开发商倾向于共同使用现有的结构,并沿着现有的路权铺设高压管线。为了与配电线路共用狭窄的通行权而扩建高压抽接线路时,会对现有配电线路的相导体和中性导体产生电压和电流。在输电系统的正常运行、故障和暂态状态下,配电中性点和相导体上可能会产生过大的感应电压和电流。应进行详细的电磁干扰研究,以评估过度建造或并联的输电线路对配电系统的影响。本文将讨论高压分接线对并联配电网产生电磁干扰的现象。还将介绍不同的实际缓解办法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study of electromagnetic interference on distribution conductors from parallel transmission line and practical mitigation solutions
The transmission line is normally built off-road due to the right of way requirements, while the distribution line is normally built on the road allowance because distribution customers are served from the road allowance. In order to connect remote renewable resources to transmission system in the vicinity, tens of kilometers of high voltage tap line is usually required. To minimize the cost and other issues in land and right of way acquisition, renewable energy developers prefer to use the existing structures jointly and route their HV tap line along the existing right of way. When HV tap line is overbuilt to share the same narrow right of way with distribution lines, it will induce voltages and currents on both phase and neutral conductors of existing distribution lines. Excessive induced voltage and current on distribution neutral and phase conductors may occur during normal operation, fault, and transient conditions of the transmission system. Detailed electromagnetic interference studies shall be conducted to assess the impact of overbuilt or parallel transmission line on the distribution system. This paper will discuss the phenomena of electromagnetic interference generated from HV tap line to the parallel distribution lines. Different practical mitigation solutions will be presented as well.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信