Wei Lai, Zhi Wang, Minyou Chen, Hongjian Xia, Dan Luo, Yunhai Wei, B. Gao, Yigao Chen
{"title":"考虑不同失效点影响的风电变流器IGBT模块可靠性评估","authors":"Wei Lai, Zhi Wang, Minyou Chen, Hongjian Xia, Dan Luo, Yunhai Wei, B. Gao, Yigao Chen","doi":"10.1109/NEMO49486.2020.9343566","DOIUrl":null,"url":null,"abstract":"With the extensive investment of wind turbine, it is significant to study the reliability and lifetime estimation model of its core components. Considering the effect of different failure sites on the remaining lifetime, the response of the converter at failure sites is studied. It is found that die attach solder fatigue and DBC (Direct Bonding Copper) solder fatigue, which happen frequently during the serving time, have different effects on thermal loads. A modified Cauer-type thermal model is proposed according to the failure sites. Using a modified lifetime model, Remaining lifetime of the DFIG (Doubly Fed Induction Generator) converter is calculated under different health conditions and failure sites. Reliability analysis is very important to the health management of converter.","PeriodicalId":305562,"journal":{"name":"2020 IEEE MTT-S International Conference on Numerical Electromagnetic and Multiphysics Modeling and Optimization (NEMO)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Reliability Evaluation of IGBT Modules in Wind Power Converter Considering the Effects of Different Failure Sites\",\"authors\":\"Wei Lai, Zhi Wang, Minyou Chen, Hongjian Xia, Dan Luo, Yunhai Wei, B. Gao, Yigao Chen\",\"doi\":\"10.1109/NEMO49486.2020.9343566\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the extensive investment of wind turbine, it is significant to study the reliability and lifetime estimation model of its core components. Considering the effect of different failure sites on the remaining lifetime, the response of the converter at failure sites is studied. It is found that die attach solder fatigue and DBC (Direct Bonding Copper) solder fatigue, which happen frequently during the serving time, have different effects on thermal loads. A modified Cauer-type thermal model is proposed according to the failure sites. Using a modified lifetime model, Remaining lifetime of the DFIG (Doubly Fed Induction Generator) converter is calculated under different health conditions and failure sites. Reliability analysis is very important to the health management of converter.\",\"PeriodicalId\":305562,\"journal\":{\"name\":\"2020 IEEE MTT-S International Conference on Numerical Electromagnetic and Multiphysics Modeling and Optimization (NEMO)\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE MTT-S International Conference on Numerical Electromagnetic and Multiphysics Modeling and Optimization (NEMO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEMO49486.2020.9343566\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE MTT-S International Conference on Numerical Electromagnetic and Multiphysics Modeling and Optimization (NEMO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEMO49486.2020.9343566","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Reliability Evaluation of IGBT Modules in Wind Power Converter Considering the Effects of Different Failure Sites
With the extensive investment of wind turbine, it is significant to study the reliability and lifetime estimation model of its core components. Considering the effect of different failure sites on the remaining lifetime, the response of the converter at failure sites is studied. It is found that die attach solder fatigue and DBC (Direct Bonding Copper) solder fatigue, which happen frequently during the serving time, have different effects on thermal loads. A modified Cauer-type thermal model is proposed according to the failure sites. Using a modified lifetime model, Remaining lifetime of the DFIG (Doubly Fed Induction Generator) converter is calculated under different health conditions and failure sites. Reliability analysis is very important to the health management of converter.