具有igct -晶闸管开关角表选择功能的有源整流控制系统动态运行研究

A. Nikolaev, I. Gilemov
{"title":"具有igct -晶闸管开关角表选择功能的有源整流控制系统动态运行研究","authors":"A. Nikolaev, I. Gilemov","doi":"10.1109/ICIEAM54945.2022.9787162","DOIUrl":null,"url":null,"abstract":"The paper investigates the dynamic operation modes of frequency converter active rectifiers with the previously proposed improved control system. This control system allows the use of IGCT thyristors switching angle tables with different switching frequencies depending on the operating mode of the frequency converter. The tables were changed when the equal control signals to the power switches of the active rectifier were generated using the current and the new tables. The research has been performed on the previously developed simulation model in the Matlab-Simulink software package. The analysis of the research results has shown the minimum disturbing effects on the regulated parameters of the active rectifier when changing the tables.","PeriodicalId":128083,"journal":{"name":"2022 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"The Dynamic Operation Investigation of an Active Rectifier Control System with IGCT-Thyristor Switching Angle Table Selection Function\",\"authors\":\"A. Nikolaev, I. Gilemov\",\"doi\":\"10.1109/ICIEAM54945.2022.9787162\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper investigates the dynamic operation modes of frequency converter active rectifiers with the previously proposed improved control system. This control system allows the use of IGCT thyristors switching angle tables with different switching frequencies depending on the operating mode of the frequency converter. The tables were changed when the equal control signals to the power switches of the active rectifier were generated using the current and the new tables. The research has been performed on the previously developed simulation model in the Matlab-Simulink software package. The analysis of the research results has shown the minimum disturbing effects on the regulated parameters of the active rectifier when changing the tables.\",\"PeriodicalId\":128083,\"journal\":{\"name\":\"2022 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIEAM54945.2022.9787162\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEAM54945.2022.9787162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文对采用改进控制系统的变频器有源整流器的动态运行模式进行了研究。该控制系统允许使用IGCT晶闸管开关角表与不同的开关频率取决于变频器的工作模式。当使用电流和新表产生对有源整流器电源开关的相等控制信号时,表被改变。在Matlab-Simulink软件包中对先前开发的仿真模型进行了研究。对研究结果的分析表明,换表对有源整流器调节参数的扰动影响最小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Dynamic Operation Investigation of an Active Rectifier Control System with IGCT-Thyristor Switching Angle Table Selection Function
The paper investigates the dynamic operation modes of frequency converter active rectifiers with the previously proposed improved control system. This control system allows the use of IGCT thyristors switching angle tables with different switching frequencies depending on the operating mode of the frequency converter. The tables were changed when the equal control signals to the power switches of the active rectifier were generated using the current and the new tables. The research has been performed on the previously developed simulation model in the Matlab-Simulink software package. The analysis of the research results has shown the minimum disturbing effects on the regulated parameters of the active rectifier when changing the tables.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信