一种具有动态相互连接的低复杂度体积模型来表示外科模拟器中的人体肝脏

Sepide Farhang, A. H. Foruzan
{"title":"一种具有动态相互连接的低复杂度体积模型来表示外科模拟器中的人体肝脏","authors":"Sepide Farhang, A. H. Foruzan","doi":"10.1504/IJMEI.2021.113392","DOIUrl":null,"url":null,"abstract":"We propose a method for visualisation of the human liver to represent nonlinear behaviour of the tissue and to preserve the object's volume. Our multi-scale model uses dynamic interconnections to keep the size of the gland. We introduce two new parameters to control the influence of an external force on the nonlinear material of the liver. Another novelty in the proposed method is to design a multi-dimension data structure which makes it possible to run our code on conventional CPUs and in real-time. We evaluated the proposed algorithm both quantitatively and qualitatively by synthetic and clinical data. Our model preserved 98.4% and 94.1% of a typical volume in small and large deformation, respectively. The run-time of our model was 0.115 second. Our model preserves the volume of a liver during both small and large deformations and our results are comparable with recent methods.","PeriodicalId":193362,"journal":{"name":"Int. J. Medical Eng. Informatics","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A low-complexity volumetric model with dynamic inter-connections to represent human liver in surgical simulators\",\"authors\":\"Sepide Farhang, A. H. Foruzan\",\"doi\":\"10.1504/IJMEI.2021.113392\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We propose a method for visualisation of the human liver to represent nonlinear behaviour of the tissue and to preserve the object's volume. Our multi-scale model uses dynamic interconnections to keep the size of the gland. We introduce two new parameters to control the influence of an external force on the nonlinear material of the liver. Another novelty in the proposed method is to design a multi-dimension data structure which makes it possible to run our code on conventional CPUs and in real-time. We evaluated the proposed algorithm both quantitatively and qualitatively by synthetic and clinical data. Our model preserved 98.4% and 94.1% of a typical volume in small and large deformation, respectively. The run-time of our model was 0.115 second. Our model preserves the volume of a liver during both small and large deformations and our results are comparable with recent methods.\",\"PeriodicalId\":193362,\"journal\":{\"name\":\"Int. J. Medical Eng. Informatics\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Int. J. Medical Eng. Informatics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1504/IJMEI.2021.113392\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Int. J. Medical Eng. Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJMEI.2021.113392","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们提出了一种人类肝脏的可视化方法,以表示组织的非线性行为并保持物体的体积。我们的多尺度模型使用动态互连来保持腺体的大小。我们引入了两个新的参数来控制外力对肝脏非线性材料的影响。该方法的另一个新颖之处是设计了一个多维数据结构,使我们的代码可以在传统的cpu上实时运行。我们通过合成和临床数据定量和定性地评估了所提出的算法。我们的模型在小变形和大变形下分别保留了98.4%和94.1%的典型体积。我们模型的运行时间为0.115秒。我们的模型保留了肝脏在大小变形期间的体积,我们的结果与最近的方法相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A low-complexity volumetric model with dynamic inter-connections to represent human liver in surgical simulators
We propose a method for visualisation of the human liver to represent nonlinear behaviour of the tissue and to preserve the object's volume. Our multi-scale model uses dynamic interconnections to keep the size of the gland. We introduce two new parameters to control the influence of an external force on the nonlinear material of the liver. Another novelty in the proposed method is to design a multi-dimension data structure which makes it possible to run our code on conventional CPUs and in real-time. We evaluated the proposed algorithm both quantitatively and qualitatively by synthetic and clinical data. Our model preserved 98.4% and 94.1% of a typical volume in small and large deformation, respectively. The run-time of our model was 0.115 second. Our model preserves the volume of a liver during both small and large deformations and our results are comparable with recent methods.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信