{"title":"一种两相交流电机固定机架三支腿逆变器电流控制新方法","authors":"Yixiao Luo, Dezhi Chen, B. Kwon, T. Lipo","doi":"10.1109/EDPE.2015.7325337","DOIUrl":null,"url":null,"abstract":"This paper proposes a novel method to control the current of a three-leg voltage source inverter (VSI) supplying a two-phase induction motor (TPIM) in the stationary frame by modulating the potential of neutral leg middle point with a proposed algorithm and using two closed loops with optimized proportional and resonant (PR) controllers to regulate the current. Two conventional current control strategies for conventional three-leg VSI in the stationary frame are presented. Then the novel control method is introduced. Both computer simulation and experiment results show the effectiveness of the proposed method in achieving better performance in terms of total harmonic distortion (THD), peak overshoot value of output current.","PeriodicalId":246203,"journal":{"name":"2015 International Conference on Electrical Drives and Power Electronics (EDPE)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A novel current control method of a three-leg inverter in the stationary frame for a two-phase AC motor\",\"authors\":\"Yixiao Luo, Dezhi Chen, B. Kwon, T. Lipo\",\"doi\":\"10.1109/EDPE.2015.7325337\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a novel method to control the current of a three-leg voltage source inverter (VSI) supplying a two-phase induction motor (TPIM) in the stationary frame by modulating the potential of neutral leg middle point with a proposed algorithm and using two closed loops with optimized proportional and resonant (PR) controllers to regulate the current. Two conventional current control strategies for conventional three-leg VSI in the stationary frame are presented. Then the novel control method is introduced. Both computer simulation and experiment results show the effectiveness of the proposed method in achieving better performance in terms of total harmonic distortion (THD), peak overshoot value of output current.\",\"PeriodicalId\":246203,\"journal\":{\"name\":\"2015 International Conference on Electrical Drives and Power Electronics (EDPE)\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Electrical Drives and Power Electronics (EDPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EDPE.2015.7325337\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Electrical Drives and Power Electronics (EDPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDPE.2015.7325337","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A novel current control method of a three-leg inverter in the stationary frame for a two-phase AC motor
This paper proposes a novel method to control the current of a three-leg voltage source inverter (VSI) supplying a two-phase induction motor (TPIM) in the stationary frame by modulating the potential of neutral leg middle point with a proposed algorithm and using two closed loops with optimized proportional and resonant (PR) controllers to regulate the current. Two conventional current control strategies for conventional three-leg VSI in the stationary frame are presented. Then the novel control method is introduced. Both computer simulation and experiment results show the effectiveness of the proposed method in achieving better performance in terms of total harmonic distortion (THD), peak overshoot value of output current.