{"title":"最大限度地减少阿曼主互联系统发电预期扩张对环境的影响","authors":"A. Malik","doi":"10.1109/SYSTEMS.2008.4519042","DOIUrl":null,"url":null,"abstract":"This paper presents the results of a study carried out to estimate the DSM energy saving potential in commercial, and government/institutional sectors of Oman and evaluates its impact on generation capacity, energy and pollutants savings in the main interconnected system. The end-use (lighting and air-conditioning) energy consumption data have been collected in two major segments of the commercial sector for simplicity. The study has found that due to DSM the capacity saving is about 300 MW, the overall energy saving is about 23.7 TWh and CO2 equivalent saving is about 13 million tons for the whole planning horizon. The total avoided cost in generation and capacity saving is about 346 million dollars.","PeriodicalId":403208,"journal":{"name":"2008 2nd Annual IEEE Systems Conference","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Minimizing the Environmental Impact of the Envisaged Expansion in Power Generation in Main Interconnected System of Oman\",\"authors\":\"A. Malik\",\"doi\":\"10.1109/SYSTEMS.2008.4519042\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the results of a study carried out to estimate the DSM energy saving potential in commercial, and government/institutional sectors of Oman and evaluates its impact on generation capacity, energy and pollutants savings in the main interconnected system. The end-use (lighting and air-conditioning) energy consumption data have been collected in two major segments of the commercial sector for simplicity. The study has found that due to DSM the capacity saving is about 300 MW, the overall energy saving is about 23.7 TWh and CO2 equivalent saving is about 13 million tons for the whole planning horizon. The total avoided cost in generation and capacity saving is about 346 million dollars.\",\"PeriodicalId\":403208,\"journal\":{\"name\":\"2008 2nd Annual IEEE Systems Conference\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 2nd Annual IEEE Systems Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SYSTEMS.2008.4519042\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 2nd Annual IEEE Systems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SYSTEMS.2008.4519042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文介绍了一项研究的结果,该研究旨在估计阿曼商业和政府/机构部门的DSM节能潜力,并评估其对主要互联系统的发电能力、能源和污染物节约的影响。为简单起见,最终用途(照明和空调)的能源消耗数据是在商业部门的两个主要部分收集的。研究发现,在整个规划范围内,由于DSM的实施,可节省容量约300兆瓦,整体节能约23.7太瓦时,节约二氧化碳当量约1300万吨。在发电和节省容量方面的总节省成本约为3.46亿美元。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Minimizing the Environmental Impact of the Envisaged Expansion in Power Generation in Main Interconnected System of Oman
This paper presents the results of a study carried out to estimate the DSM energy saving potential in commercial, and government/institutional sectors of Oman and evaluates its impact on generation capacity, energy and pollutants savings in the main interconnected system. The end-use (lighting and air-conditioning) energy consumption data have been collected in two major segments of the commercial sector for simplicity. The study has found that due to DSM the capacity saving is about 300 MW, the overall energy saving is about 23.7 TWh and CO2 equivalent saving is about 13 million tons for the whole planning horizon. The total avoided cost in generation and capacity saving is about 346 million dollars.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信